- access the technical parameters as explained in the section" Accessing
the technical parameters"
- select VENT CYCLE with the "UP" and "DOWN" keys, confirming the
selection
WEATHER COMPENSATION
COMBUSTION ANALYSIS
AIR PURGING CYCLE
INSTALLER
- select END FUNCTION with the "UP" and "DOWN" keys , confirming
the selection.
AIR PURGING CYCLE
FUNCTION ENABLED
FUNCTION DISABLED
STOP FUNCTION
INSTALLER
The REC10 will briefly display a wait message after which you will
automatically be taken to the main screen.
The vent cycle can also be interrupted, if the boiler is not set to OFF, by a
domestic hot water request.
FRI
18/05/2013
MENU
INFO
HOT WATER TEMPERATURE
SUMMER
: selecting SUMMER operating mode in the STATUS menu
and then BOILER, the traditional function of just domestic hot water will be
activated. The REC10 normally displays the temperature of the domestic
hot water supplied by the boiler.
HOT WATER ONLY
HEATING AND HOT WATER
WINTER
/
: selecting WINTER in the STATUS menu and then
BOILER, the heating and domestic hot water functions are activated.
REC10 normally displays the domestic hot water temperature unless
there is a heating request in progress, in which case the boiler's outlet
temperature is displayed.
TECHNICAL
RANGE RATED
CALIBRATION
PLANT
12:17
bar
1.3
STATE
°C
30
.3
SET
BOILER
OFF
HOT WATER ONLY
HEATING AND HOT WATER
5.4
Adjusting the heating water temperature without
an outdoor temperature sensor connected
When there is no outdoor temperature sensor, the boiler operates at a
fixed-point, the HEATING setpoint in this case can be set selecting SET on
the main screen of the REC10 and selecting the desired value within the
range [40°C - 80.5°C] for high temperature systems rather than [20°C - 45
°C] for low temperature systems.
5.5
Adjusting the heating water temperature with an
outdoor temperature sensor connected
When an outdoor temperature sensor is installed, the outlet temperature
is automatically selected by the system, which quickly adjusts the ambient
temperature according to the variations in the outdoor temperature. If you
want to change the temperature, raising it or lowering it with respect to that
automatically calculated by the electronic board, it is possible to change the
HEATING setpoint by selecting SET on the main screen of the REC10 and
selecting within the range (-5 - +5) the desired comfort level (see section
"Setting the thermoregulation").
Note: when there is an outdoor temperature sensor connected it is still
possible to have the boiler operate at a fixed point setting the values of MIN
SP HEAT and MAX SP HEAT at the desired HEATING setpoint.
5.6
Adjusting the domestic hot water temperature
To adjust the domestic hot water temperature (bath, shower, kitchen, etc.),
set the DOMESTIC HOT WATER setpoint selecting SET on the main
screen of the REC10 and selecting the desired value within the range
[37.5°C - 60°C].
BOILER
OFF
SET
HEATING
DHW
PREHEATING
SET
HEATING
DHW
PREHEATING
ENGLISH
21