(Fig. 16)
Twin pipes (ø 80 mm)
The combustion air suction pipe should be selected from the two inputs,
remove the closing plug fi xed with the screws and fi x the specifi c air
defl ector.
Position the adaptor on the fl ue gases pipe so that the Ø 60 pipe goes fully
up against the fl ue gases turret of the boiler.
- Once positioned, make sure that the 4 notches (A) on the fl ange connect
to the groove (B) on the Ø 100 of the adaptor.
- Fully tighten the screws (C) that tighten the two locking terminals of the
fl ange so the adaptor itself is restrained.
If the Ø 60-100 to Ø 80-80 splitter kit is used instead of the twin pipe system,
there is a loss in the maximum lengths as shown in the table.
Place the splitter so that the Ø 60 pipe goes fully up against the fl ue gases
turret of the boiler.
Once positioned, make sure that the 4 notches (A) on the fl ange connect to
the groove (B) on the Ø 100 of the splitter.
Fully tighten the screws (C) that tighten the two locking terminals of the
fl ange so the adaptor itself is restrained.
Loss of length (m)
Coaxial pipes (ø 80-125 mm)
- Place the adaptor vertical attachment so that the Ø 60 pipe goes fully up
against the fl ue gases turret of the boiler.
- Once positioned, make sure that the 4 notches (A) on the fl ange connect
to the groove (B) on the Ø 100 of the adaptor.
- Fully tighten the screws (C) that tighten the two locking terminals of the
fl ange so the adaptor itself is restrained.
- Then fi t the Ø 80-125 adaptor kit on the vertical fi tting
Twin pipes with Ø 80 pipework Ø50 - Ø60 - Ø80)
Thanks to the boiler characteristics, a Ø80 fl ue gas exhaust pipe can be
connected to the Ø50 - Ø60 - Ø80 piping ranges.
b
For the pipe, you are advised to make a project calculation in order
to respect the relevant regulations in force.
The table shows the standard confi gurations allowed.
Table of standard pipe confi guration (*)
1 Bend 90° Ø 80
Air suction
4.5m pipe Ø80
1 Bend 90° Ø 80
4.5m pipe Ø80
Flue gas discharge
Reduction from Ø80 to Ø50 from Ø80 to Ø60
Flue base bend 90°, Ø50 or Ø60 or Ø80
For ducting pipe lengths see table
(*) Use fl ue gas system accessories made of plastic (PP) for condensing
boilers: Ø50 and Ø80 class H1 and Ø60 class P1.
The boilers are factory set to:
25 KIS: 6,200 r.p.m. in heating mode and 7.600 in domestic hot water mode
and the maximum attainable length is 5m for the Ø 50 pipe, 18 m for the Ø
60 pipe and 98 m for the Ø 80 pipe.
30 KIS: 5,800 rpm in heating mode and 6,900 in domestic hot water mode,
and the maximum length that can be reached is 2m for the Ø50 and 11 m
for the Ø60 pipe and 53 m for the Ø80 pipe.
35 KIS: 6,900 rpm in heating mode and 7.800 in domestic hot water mode,
and the maximum length that can be reached is 2m for the Ø50 pipe and 11
m for the Ø60 pipe and 57 m for the Ø80 pipe.
Should greater lengths be required, compensate the pressure drop with
an increase in the r.p.m.of the fan, as shown in the adjustments table, to
provide the rated heat input.
b
The minimum calibration should not be modifi ed.
Ø50
Ø60
Ø80
5.5 for flue gases pipe
0.5
1.2
7.5 for air pipe
(Fig. 17)
(Fig. 18)

Table of adjustments

Fan rotations
r.p.m.
Heating
DHW
6200
7600
6300
7700
6400
7800
6,500
7900
6600
8,000
25 KIS
6700
8100
6800
8200
6900
8300
7,000
8400
7100
8,500
5800
6900
5900
7,000
6000
7100
6100
7200
6200
7300
30 KIS
6300
7400
6400
7500
6,500
7600
6600
7700
6700
7800
6900
7800
7,000
7900
7100
8,000
7200
8100
7300
8200
35 KIS
7400
8300
7500
8400
7600
8,500
7700
8600
7800
8700
(*)
Maximum length that can be installed ONLY with class H1 discharge
pipes.
The Ø50 or Ø60 or Ø80 confi gurations contain Lab test data. In the event of
installations that diff er from the indications in the "standard confi gurations"
and "adjustments" tables, refer to the equivalent linear lengths below.
b
In any case, the maximum lengths declared in the booklet are guaranteed,
and it is essential not to exceed them.
COMPONENT Ø 50
Bend 45° Ø 50
Bend 90° Ø 50
Extension 0.5m Ø 50
Extension 1.0m Ø 50
Extension 2.0m Ø 50
COMPONENT Ø 60
Bend 45° Ø 60
Bend 90° Ø 60
Extension 0.5m Ø 60
Extension 1.0m Ø 60
Extension 2.0m Ø 60
Pipework ducts
Maximum length [m]
Ø 50
Ø 60
Ø 80
5
18
98
7 (*)
23 (*)
125 (*)
9 (*)
28 (*)
153 (*)
11 (*)
33 (*)
181 (*)
13 (*)
38 (*)
208 (*)
15 (*)
43 (*)
236 (*)
17 (*)
48 (*)
263 (*)
19 (*)
53 (*)
291 (*)
22 (*)
58 (*)
319 (*)
24 (*)
63 (*)
346 (*)
2
11
53
4
15
73
5 (*)
19 (*)
93 (*)
7 (*)
24 (*)
113 (*)
9 (*)
28 (*)
133 (*)
10 (*)
32 (*)
153 (*)
12 (*)
36 (*)
173 (*)
14 (*)
40 (*)
193 (*)
16 (*)
44 (*)
214 (*)
17 (*)
49 (*)
234 (*)
2
11
57
3 (*)
15 (*)
75 (*)
4 (*)
19 (*)
93 (*)
6 (*)
22 (*)
112 (*)
7 (*)
26 (*)
130 (*)
9 (*)
30 (*)
148 (*)
10 (*)
33 (*)
166 (*)
12 (*)
37 (*)
184 (*)
13 (*)
40 (*)
202 (*)
15 (*)
44 (*)
220 (*)
Linear equivalent in metres Ø80 (m)
12.3
19.6
6.1
13.5
29.5
Linear equivalent in metres Ø80 (m)
5
8
2.5
5.5
12
ENGLISH
ΔP at
boiler
outlet
Pa
174
213
253
292
332
371
410
450
489
528
150
189
229
268
308
347
386
426
465
504
190
229
269
308
348
387
426
466
505