Alarms Log; Switching Off For Lengthy Periods; System Reset; Temporary Switch-Off - Riello Family KIS Series Installer And User Manual

Table of Contents

Advertisement

Available languages

Available languages

FAMILY CX

5.16 Alarms log

The ALARMS LOG function is automatically enabled only after the machine
has been powered up for at least 2 consecutive hours, during this period of
time any alarms that arise would not be saved in the "alarms log".
The alarms can be displayed in chronological order, from the most recent
to the oldest, up to a maximum of 50 alarms; to display the alarms log:
- access the technical parameters as explained in the section" Accessing
the technical parameters".
- select ALARMS LOG with the "UP" and "DOWN" keys , confirming the
selection
COMBUSTION ANALYSIS
EXHAUST PROBE RESET
ERROR HISTORY
INSTALLER
- scroll through the alarms log with the "UP" and "DOWN" keys; for each
alarms a sequential number is displayed, an error code and the date and
time the alarm occurred.
1 - 10:30 18/11/2013
USE ARROW KEYS TO SEE OTHER ANOMALIES
it is possible to return to the start page at any time by keeping the "BACK"
key pressed for at least 2 seconds.
Note: Once enabled, the ALARMS LOG function can no longer be
disabled; there is no procedure for resetting the alarms log.
If an alarm repeats consecutively, it is saved only once.
5.17 Temporary switch-off
In the event of temporary absences (weekends, short breaks, etc.) set the
status of the boiler to OFF
.
HOT WATER ONLY
HEATING AND HOT WATER
While the electrical supply and the fuel supply remain active, the boiler is
protected by the systems:
- heating anti-freeze: this function is activated if the temperature
measured by the flow sensor drops below 5°C. A heat request is
generated in this phase with the ignition of the burner at minimum output,
which is maintained until the outlet water temperature reaches 35° C;
- domestic hot water anti-freeze: this function is activated if the
temperature measured by the domestic hot water probe drops below
5°C. A heat request is generated in this phase with the ignition of the
28
TECHNICAL
RANGE RATED
CALIBRATION
E030
FAN ERROR
BOILER
OFF
burner at minimum output, which is maintained until the outlet water
temperature reaches 55° C.
b
The activation of the ANTI-FREEZE function is indicated by a
scrolling message on the foot of the REC10 display.
- circulator anti-locking : the circulator activates every 24 hours of
stoppage for 30 seconds.
5.18 Switching off for lengthy periods
The long term non use of the Family boiler causes the following operations
to be carried out:
- set the status of the boiler to
- Set the system's main switch to "off"
- Close the fuel and water taps of the heating and domestic hot water
system.
In this case, the anti-freeze and anti-blocking systems are deactivated.
Drain the heating and domestic water system if there is any risk of freezing.
HOT WATER ONLY
HEATING AND HOT WATER
Closing
position

5.19 System reset

b
This operation must be carried out only by professionally qualifi ed
personnel.
Whenever necessary, it is possible to restore the factory settings by
carrying out a SYSTEM RESET:
- access the technical parameters as explained in the section" Accessing
the technical parameters".
- select INSTALLATION with the "UP" and "DOWN" keys , confirming the
selection
INSTALLATION
WEATHER COMPENSATION
INSTALLER
BOILER
OFF
TECHNICAL
PARAMETERS
RANGE RATED
CALIBRATION

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Family 25 kisFamily 30 kisFamily 35 kis

Table of Contents