Display and fault codes
When there is an operating fault a
flashing code is shown on the display
and the red led comes on in the event
of a definitive lockout.
For a description of the faults, refer to
the table below.
CODE DESCRIPTION OF TYPE OF
AL10
NUMBER OF IGNITION ATTEMPTS EXCEEDED (FLAME ABSENT/
CONDENSATION PRESENT)
AL20
LIMIT THERMOSTAT FAULT
AL21
LOW
TEMPERATURE
SAFETY FAULT
AL26
RETURN LINE OVERTEMPERATURE
AL28
RETURN LINE/OUTLET PROBE DIFFERENTIAL FAULT
AL29
FLUE GASES PROBE OVERTEMPERATURE
AL34
TACKO FAN FAULT
AL40
SYSTEM WATER PRESSURE LOW (AFTER 10 MINUTES)
AL41
SYSTEM WATER PRESSURE LOW
AL52
GENERAL ELECTRONIC FAULT
AL55
FAULT DUE TO ABSENCE OF BOILER MODE CONFIGURATION
(CORRESPONDING JUMPER ABSENT)
AL60
DOMESTIC HOT WATER PROBE FAULT/WATER TANK PROBE
FAULT (IS i model)
AL71
OUTLET PROBE FAULT (OPEN/SHORT CIRCUIT)
AL73
RETURN LINE PROBE FAULT (OPEN/SHORT CIRCUIT)
AL79
OUTLET OVERTEMPERATURE/ RETURN LINE/OUTLET PROBE
DIFFERENTIAL FAULT
AL91
PRIMARY HEAT EXCHANGER CLEANING (CALL CUSTOMER SER-
VICE)
Resetting the faults
Wait about 10 seconds before resetting
normal operation conditions.
Then proceed as follows:
1) Display of the flashing alarm code
If just the flashing alarm is displayed
it means that a temporary stop was
diagnosed, if the fault is reset the
THERMOSTAT/CONDENSATION
31
Faults and solutions
LOCKOUT
LOCKOUT
LOCKOUT
PUMP
LOCKOUT
LOCKOUT
LOCKOUT
LOCKOUT
LOCKOUT
LOCKOUT
STOP
LOCKOUT
LOCKOUT
SEE DEDICATED
PART
STOP
STOP
LOCKOUT
SIGNAL