RESIDENCE
Domestic hot water REQUEST, the tap icon blinks:
OFF
ƒ Set the boiler to the OFF status by pressing key 1 until the central
segments are displayed.
4.8
Adjusting the heating water temperature without
an outdoor temperature sensor connected
If there is no outdoor temperature sensor the boiler operates at a fixed
point, the HEATING setpoint in this case can be set on the main page of
the screen.
Pressing the key C or D displays the current heating setpoint; the value
blinks with a frequency of 0.5 sec ON, 0.5 sec OFF and the icons
come on.
+
The successive pressing of the key C or D allows you to set the value of the
heating setpoint within the preset range:
[40°C - 80.5°C] for high temperature systems
[20°C - 45 °C] for low temperature systems
with steps of 0.5°C.
The level bars beside the heating icon show the setpoint value set with
respect to the operating range:
- four bars on = max setpoint
- one bar on = min setpoint
Keeping one of the two keys C or D pressed for longer, the meter increases
the speed of advancement modifying the set value.
If no key is pressed for 5sec, the value set is taken as the new heating
setpoint and the display returns to the main page.
22
DAY
+
C
D
RESET
MENU
4.9
Adjusting the heating water temperature with an
outdoor temperature sensor connected
If an outdoor temperature sensor is installed and thermoregulation is enabled
(parameter OTR=1), the delivery temperature is automatically selected by
the system, which quickly adjusts the ambient temperature according to the
variations in the outdoor temperature.
If you want to change the temperature, raising it or lowering it with respect
to the temperature automatically calculated by the electronic board, it is
possible to change the HEATING setpoint as follows:
Press the keys C or D and select the desired level of comfort within the range
(-5 - +5) (see paragraph "4.5 Setting the thermoregulation" ).
and
Note: if an outdoor temperature sensor is connected it is in any event
possible to have the boiler operate at a fixed point by setting the parameter
OTR = 0 (menu CH).

4.10 Adjusting the domestic hot water temperature

On the main screen, pressing the key A rather than B displays the current
domestic hot water setpoint, the value blinks with a frequency of 0.5 sec
ON, 0.5 sec OFF and the icons
A
B
The successive pressing of the keys A or B allows you to set the value
of the domestic hot water setpoint raising or lowering the value within the
preset range in steps of 0.5°C.
The level bars beside the heating icon show the setpoint value set with
respect to the operating range: