Creation options
The CPU and SINAMICS Integrated are by default created in a shared group folder in the
project tree.
To change this behavior, activate or deactivate the relevant options for the SIMATIC Drive
Controller under "Settings" -> "Hardware configuration" -> "Device-specific settings".
Figure 7-3
Creation options for creating a SIMATIC Drive Controller
The table below sets out the benefits of configuration with or without grouping.
Table 7- 2
With "Drive Controller" grouping
•
•
If you want to create the SIMATIC Drive Controller without the integrated drive, deselect the
"Including SINAMICS Integrated" option.
Deselecting this option can, for example, be useful in the following cases:
● You are copying a previously configured SINAMICS Integrated drive control from another
project.
● The project is to be processed by another user without SINAMICS Startdrive.
● SINAMICS Integrated is not to be configured until later.
● SINAMICS Integrated is not being used, for example, because another drive system is
being used.
SIMATIC Drive Controller
System Manual, 11/2019, A5E46600094-AA
Guide to grouping
Actions apply to all devices in a group, for
example
–
Go online
–
Load to/from device
–
Copy
You can add additional devices to the group
as required, for example
–
with CU320-2
–
with I/O system
7.3 Configuration procedure
Without grouping or user-specific grouping
Greater flexibility in project structure in the
•
project tree, for example
–
by machine/plant modules
–
by CPUs and drives, in separate groups
Configuring