  • Page 2 ___________________ Preface ___________________ Documentation guide ___________________ SIMATIC Product overview ___________________ Wiring S7-1500/ET 200MP Digital output module ___________________ DQ 16x230VAC/2A ST Relay Parameters/address space (6ES7522-5HH00-0AB0) ___________________ Interrupts/diagnostics alarms Manual ___________________ Technical specifications ___________________ Dimensional drawing ___________________ Parameter data records 07/2017 A5E34934019-AC...
  • Page 3 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 4: Preface

    Purpose of the documentation This manual supplements the system manual S7-1500/ET 200MP (https://support.industry.siemens.com/cs/ww/en/view/59191792). Functions that relate in general to the systems are described in this system manual. The information provided in this manual and in the system/function manuals supports you in commissioning the systems.
  • Page 5 In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial security concept. Siemens’ products and solutions only form one element of such a concept. Customer is responsible to prevent unauthorized access to its plants, systems, machines and networks.
  • Page 6: Table Of Contents

    Table of contents Preface ..............................4 Documentation guide ..........................7 Product overview ..........................10 Properties ..........................10 Wiring ..............................12 Parameters/address space ........................15 Parameters ..........................15 Declaration of parameters ...................... 16 Address space ........................16 Interrupts/diagnostics alarms......................... 22 Status and error displays ....................... 22 Interrupts ..........................
  • Page 7: Documentation Guide

    This arrangement enables you to access the specific content you require. Basic information The System Manual and Getting Started describe in detail the configuration, installation, wiring and commissioning of the SIMATIC S7-1500 and ET 200MP systems. The STEP 7 online help supports you in the configuration and programming. Device information Product manuals contain a compact description of the module-specific information, such as properties, wiring diagrams, characteristics and technical specifications.
  • Page 8 Documentation guide Manual Collection S7-1500/ET 200MP The Manual Collection contains the complete documentation on the SIMATIC S7-1500 automation system and the ET 200MP distributed I/O system gathered together in one file. You can find the Manual Collection on the Internet (https://support.industry.siemens.com/cs/ww/en/view/86140384).
  • Page 9 Solutions are shown in interplay with multiple components in the system - separated from the focus on individual products. You will find the application examples on the Internet (https://support.industry.siemens.com/sc/ww/en/sc/2054). See also TIA Selection Tool (http://w3.siemens.com/mcms/topics/en/simatic/tia-selection-tool) SAT (https://support.industry.siemens.com/cs/ww/en/view/98161300) PRONETA (https://support.industry.siemens.com/cs/ww/en/view/67460624) Digital output module DQ 16x230VAC/2A ST Relay (6ES7522-5HH00-0AB0) Manual, 07/2017, A5E34934019-AC...
  • Page 10: Product Overview

    Product overview Properties Article number 6ES7522-5HH00-0AB0 View of the module Figure 2-1 View of the DQ 16x230VAC/2A ST module Properties The module has the following technical properties: ● 16 digital outputs (relays) ● Supply voltage of the 24 V DC relay coils ●...
  • Page 11 Other components The following component can be ordered separately: Front connectors, including potential jumpers and cable ties For more information on accessories, refer to the S7-1500/ET 200MP system manual (https://support.industry.siemens.com/cs/ww/en/view/59191792). Digital output module DQ 16x230VAC/2A ST Relay (6ES7522-5HH00-0AB0) Manual, 07/2017, A5E34934019-AC...
  • Page 12: Wiring

    This section contains the block diagram of the module and outlines various wiring options. You will find information on wiring the front connector, establishing a cable shield, etc in the S7-1500/ET 200MP system manual (https://support.industry.siemens.com/cs/ww/en/view/59191792) in section Wiring. Digital output module DQ 16x230VAC/2A ST Relay (6ES7522-5HH00-0AB0) Manual, 07/2017, A5E34934019-AC...
  • Page 13 Wiring Wiring and block diagram The example in the following figure shows the terminal assignment and the assignment of the channels. The individual channels are connected with a relay. Note Note that the 24 V DC supply voltage for this module must always be supplied by terminals 19/20 and 39/40.
  • Page 14 Wiring Tip: Using the potential jumpers Use the potential jumpers supplied with the front connector if you want to distribute the 24 V DC supply voltage to a neighboring module. This helps you to avoid having to terminate two wires to one terminal. Proceed as follows: 1.
  • Page 15: Parameters/Address Space

    Parameters/address space Parameters DQ 16x230VAC/2A ST parameters When you assign the module parameters in STEP 7, you use various parameters to specify the module properties. The table below lists the parameters that can be set. The effective range of the configurable parameters depends on the type of configuration. The following configurations are possible: ●...
  • Page 16: Declaration Of Parameters

    Parameters/address space 4.2 Declaration of parameters Declaration of parameters No supply voltage L+ Enabling of the diagnostics at no or insufficient supply voltage L+. Reaction to CPU STOP Determines the reaction of the output to the CPU going into STOP state or when the connection to the CPU is interrupted.
  • Page 17 Parameters/address space 4.3 Address space Value status (Quality Information, QI) The value status is always activated for the following modules: ● DQ 16x230VAC/2A ST QI ● DQ 16x230VAC/2A ST S QI ● DQ 16x230VAC/2A ST MSO An additional bit is assigned to each channel for the value status. The bit for the value status indicates if the output value specified by the user program is actually pending at the module terminal (0 = value is incorrect).
  • Page 18 Parameters/address space 4.3 Address space Address space for configuration as 2 x 8-channel DQ 16x230VAC/2A ST S QI For the configuration as a 2 x 8-channel module, the channels of the module are divided into two submodules. The submodules can be assigned to different IO controllers when the module is used in a shared device.
  • Page 19 Parameters/address space 4.3 Address space Address space for configuration as 1 x 16-channel DQ 16x230VAC/2A ST MSO For the configuration as a 1 x 16-channel module (module-internal Shared Output, MSO), channels 0 to 15 of the module are copied to multiple submodules. Channels 0 to 15 are then available with identical values in various submodules.
  • Page 20 Parameters/address space 4.3 Address space The figure below shows the assignment of the address space for submodules 1 and 2 and the value status. Figure 4-3 Address space for configuration as 1 x 16-channel DQ 16x230VAC/2A ST MSO with value status Digital output module DQ 16x230VAC/2A ST Relay (6ES7522-5HH00-0AB0) Manual, 07/2017, A5E34934019-AC...
  • Page 21 Reference You will find information on the module-internal shared input/shared output (MSI/MSO) function in the function manual PROFINET with STEP 7 V13 (http://support.automation.siemens.com/WW/view/en/49948856) in the section Module- internal shared input/shared output (MSI/MSO). Digital output module DQ 16x230VAC/2A ST Relay (6ES7522-5HH00-0AB0)
  • Page 22: Interrupts/Diagnostics Alarms

    Interrupts/diagnostics alarms Status and error displays LED displays The figure below shows the LED displays (status and error displays) of the DQ 16x230VAC/2A ST. Figure 5-1 LED displays of the module DQ 16x230VAC/2A ST Digital output module DQ 16x230VAC/2A ST Relay (6ES7522-5HH00-0AB0) Manual, 07/2017, A5E34934019-AC...
  • Page 23 Interrupts/diagnostics alarms 5.1 Status and error displays Meaning of the LED displays The following tables explain the meaning of the status and error displays. Corrective measures for diagnostics alarms can be found in the section Diagnostics alarms (Page 24). RUN and ERROR LED Table 5- 1 RUN and ERROR status and error displays Meaning...
  • Page 24: Interrupts

    Interrupts/diagnostics alarms 5.2 Interrupts Interrupts Digital output module DQ 16x230VAC/2A ST supports diagnostic interrupts. You can find detailed information on the event in the error organization block with the "RALRM" instruction (read additional interrupt info) and in the STEP 7 online help. Diagnostic interrupt The module generates a diagnostic interrupt at the following event: ●...
  • Page 25: Technical Specifications

    Technical specifications Technical specifications of the DQ 16x230VAC/2A ST Article number 6ES7522-5HH00-0AB0 General information Product type designation DQ 16x230VAC/2A ST (relay) HW functional status FS01 Firmware version V1.0.0 FW update possible • Product function Yes; I&M0 to I&M3 I&M data •...
  • Page 26 Technical specifications Article number 6ES7522-5HH00-0AB0 Power Power available from the backplane bus 0.8 W Power loss Power loss, typ. Digital outputs Number of digital outputs Current-sinking Current-sourcing Short-circuit protection Controlling a digital input Switching capacity of the outputs 50 W (230 V AC), 5 W (24 V DC) on lamp load, max.
  • Page 27 Technical specifications Article number 6ES7522-5HH00-0AB0 Switching capacity of contacts 2 A; see additional description in the manual – with inductive load, max. 2 A; see additional description in the manual – with resistive load, max. Cable length 1 000 m shielded, max.
  • Page 28 Technical specifications Article number 6ES7522-5HH00-0AB0 Isolation Isolation tested with Between channels: 3 100 V DC; between chan- nels backplane bus: 3 100 V DC; between L+ and backplane bus: 707 V DC (type test) Ambient conditions Ambient temperature during operation 0 °C horizontal installation, min.
  • Page 29 Technical specifications Details on the number of switching cycles The following tables list the permissible number of switching cycles depending on the applied voltage and current load. Different values apply in each case to resistive and inductive loads. Table 6- 1 Switching capacity and service life of relay contacts for resistive load For resistive load Voltage...
  • Page 30 Technical specifications Power reduction (derating) of outputs according to number of channels The following graphs show the loading capacity of the relay contacts in relation to the mounting position of the S71500 automation system/ET 200MP distributed I/O system and the ambient temperature. The total current of the outputs remains unaffected. ①...
  • Page 31: Dimensional Drawing

    Dimensional drawing The dimension drawing of the module on the mounting rail, as well as a dimension drawing with open front cover, are provided in the appendix. Always observe the specified dimensions for installation in cabinets, control rooms, etc. Figure A-1 Dimension drawing of the DQ 16x230VAC/2A ST module Digital output module DQ 16x230VAC/2A ST Relay (6ES7522-5HH00-0AB0) Manual, 07/2017, A5E34934019-AC...
  • Page 32 Dimensional drawing Figure A-2 Dimension drawing of the DQ 16x230VAC/2A ST module, side view with open front cover Digital output module DQ 16x230VAC/2A ST Relay (6ES7522-5HH00-0AB0) Manual, 07/2017, A5E34934019-AC...
  • Page 33: Parameter Data Records

    Parameter data records Parameter assignment and structure of the parameter data records The data records of the module have an identical structure, regardless of whether you configure the module with PROFIBUS DP or PROFINET IO. Dependencies for configuration with GSD file When a GSD file is used to configure a module, dependencies can arise when "assigning the parameters".
  • Page 34 Parameter data records B.1 Parameter assignment and structure of the parameter data records Assignment of data record and channel For the configuration as a 1 x 16-channel module, the parameters are located in data records 64 to 79 and are assigned as follows: ●...