Alpha ESS Storion-SMILE5 Installation, Operation & Maintenance Manual page 51

Energy storage system (ess)
Hide thumbs Also See for Storion-SMILE5:
Table of Contents

Advertisement

Step 8: Click the Grid Function to set up
relevant parameters about the grid
Step 10: Click Function-System Mode to set
system mode: DC, AC, Hybrid.
Step 12: If you want to use force charge, sett
Enable here.
Step 14: Set the UPS Reserve SOC, it means
how much battery energy to keep for UPS
function.
___________________________________________________________________
EMS Introduction and Set up
please set it Yes.
Step 9: Set the Max. Feed in rate value.
Step 11: Click the mode then set up work
mode.(self-use or force time charge)
Step 13: Set the charge and discharge time.
Step 15: Click Safety in the setting menu. Set
safety standard.
AS4777 for Australia, ARN4105 for Germany,
CEI0_21 for Italy, G83_2 for Great Britain,
NRS097_2_1 for South Africa, RD1699 for
Spain, VDE0216 for 60Hz countries.
Alpha ESS Co., Ltd.
Your Smart Energy
Page 49