I/O Address Map

20.4
The I/O-port addresses of the processor module MOPS/386A are functionally identical to a
standard PC/AT. All addresses not mentioned in this table should be available. We
recommend that you do not use I/O addresses below 0110hex with additional hardware for
compatibility reasons, even if they are available on the MOPS/386A.
I/O
Addresses
0000-000Fh
0020-003Fh
0040-0043h
0050-005Fh
0060-0064h
0070-0071h
0080-008Fh
0092h
00A0-00BFh
00C0-00DEh
00EC-00EFh
00F0-00FFh
01F0-01F8h
0278-027Fh
02E8-02EFh
02F8-02FFh
0300-030Fh
0370-0377h
0378-037Fh
03BC-03C4h
03E8-03Efh
03F0-03F7h
03F8-02FFh
Note: The Super I/O Controller is connected to ISA address lines A0 to A10. The I/O port
addresses of the SMsC FDC37C669 will be mirrored every 800hex in the I/O address
space.
System Resource Allocations
Use
DMA Controller 1
Interrupt Controller 1
Counter/timer
Onboard control registers
Keyboard controller
Real-time clock
DMA page register 74LS612
Port A register (Fast A20 Gate)
Interrupt Controller 2
DMA Controller 2
Configuration registers
Math coprocessor
Fixed disk
Parallel Port 2
User specific Serial Port
(COM4)
Serial Port 2
Onboard Ethernet
Configuration Port
Parallel Port 1
User-specific Parallel Port
User-specific Serial Port
(COM3)
Diskette controller
Serial Port 1
48
Available
Comment
No
No
No
No
No
No
No
No
No
No
No
No
No
Yes
Free in standard configuration,
but possible address of LPT.
Yes
Free in standard configuration,
but possible address of COM.
No
Default for COM B, free with
different configuration.
No
The Ethernet controller can be
configured to another I/O port
address with the setup tool; it
cannot be disabled.
No
Configuration address for SMC-
controller.
No
Default for LPT 1; free with
different configuration.
Yes
Free in standard configuration
but possible address of LPT.
Yes
Free in standard configuration,
but possible address of COM.
No
No
Default for COM A; free if
different configuration used.
MOPS/386A User's Guide
Kontron
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed.

Advertisement

Table of Contents
loading

Table of Contents