Dte Options Screen - General DataComm SpectraComm 800 T3 Installation & Operation Manual

Data service unit
Table of Contents

Advertisement

SC800 T3 Operation

DTE Options Screen

At the SC800 T3 Configuration Menu, press 2 and then press Enter to access the DTE Options
screen, shown below.
Table 3-5
DTE Options
Option
[1] DTE Loop Timeout
[2] DTE Test
[3] DCE Ready
[4] DTE Data Rate
[CR] Return to Previous Menu
[S] Save
[0] Return to Main Menu
Note
DTE option [4] selects one of 14 available data subrates.This option is only available on SC800 T3 DSU
cards at Firmware Revision 02.00.00 or greater. To upgrade a lower version card, contact your GDC service
representative.
3-8
Table 3-5
describes the terminal interface selections.
Enabled or
Disabled
remotely generated DTE loop after a ten minute time-out.
Disabled
Enabled or
Forces the control lead DCE Ready on regardless of the data-passing
mode of the DSU:
Selects data rates (Kbps): 3200, 6300, 9500, 12600, 15800, 18900,
22100, 25300, 28400, 31600, 34700, 37900, 41100,
Press Enter (Carriage Return) to return to the Configuration Menu.
Saves changes made at the DTE Options screen.
Displays confirmation prompt, then exits the Configuration menu
without saving changes; returns to SC800 T3 Main Menu.
SpectraComm 800 T3 Data Service Unit
Installation and Operation Manual
SC800 T3 Configuration Menu
Description/Settings
- When enabled, this option deactivates a
-The activation of loops generated by the DTE.
Follows DTE Ready
(default), Forced On.
44210
.
076R160-000
Issue 4