Firmware Download Menu - General DataComm SpectraComm 800 T3 Installation & Operation Manual

Data service unit
Table of Contents

Advertisement

SC800 T3 Operation

Firmware Download Menu

At the SC800 T3 Maintenance screen, press 3, then press Enter to access the Firmware
Download submenu, shown below.
procedures.
Table 3-10
Firmware Download Menu
Display / Selection
Active Firmware Revision
Standby Firmware Version
Standby Firmware Status
Download Mode
Download Status
[1] Switch to Standby
Firmware
[2] Disable All Downloads
[3] Enable Downloads and
Store Zipped
[4] Enable Downloads, Unzip
and Execute
[CR] Return to Previous Menu
[0] Return to Main Menu
3-20
Table 3-10
Read-only display of firmware revision that is currently operating in the unit.
Read-only display standby firmware revision stored in zipped (compressed) format.
Read-only status display of firmware status:
[ blank ] indicates new unit with no standby firmware loaded.
Invalid -
Valid - OK
indicates standby firmware loaded and ready for use
Invalid - Checksum Failed
download.
Invalid - Download Aborted
Invalid-Unzip Failed
firmware.
Read-only display of the unit's response to an imminent firmware download. This Enable/
Disable setting remains in effect until changed by the user.
Read-only display of the firmware download process: Idle or In Progress.
Commands the unit to unzip (decompress) the stored inactive firmware and place it into
service as the current operating firmware.
Commands the unit to reject any imminent download of firmware.
Commands the unit to clear the standby firmware, accept an imminent firmware download
and store it as the zipped, inactive Standby Firmware.
Command the unit to clear the standby firmware, accept an imminent firmware download,
unzip it and place it into operation as Active. Simultaneously zips and stores the
previously operating firmware as inactive Standby Firmware.
Returns to the SC800 T3 Maintenance screen.
Returns to the SC800 T3 Main Menu.
SpectraComm 800 T3 Data Service Unit
Installation and Operation Manual
SC800 T3 Maintenance Screen
describes the menu selections, followed by
Description
indicates standby firmware corrupted during
indicates download aborted in progress by SCM.
indicates problem occurred during unzip of standby
076R160-000
Issue 4

Advertisement

Table of Contents
loading

Table of Contents