Technical Specifications - General DataComm SpectraComm 800 T3 Installation & Operation Manual

Data service unit
Table of Contents

Advertisement

Introduction and Specifications

Technical Specifications

The following table describes the physical, operational, and environmental specifications for the
SpectraComm 800 T3 DSU. Conforming to these specifications ensures maximum system
performance and reduces the chances of mechanical breakdown and personnel hazard.
Table 1-3
SpectraComm 800 T3 Card Specifications
Type
DS3 Network
Interface
Customer
Interface
Diagnostics
Electrical
Physical
Dimensions
Environment
1-6
Specification
Description
Data Rates
T3 Network interface is 44.736 Mbps.
T3 Payload through the HSSI port is 3 to 44.2 Mbps in 3 Mbps
increments.
Communication Line
T3 Digital Carrier
Line Impedance
75 Ohms, unbalanced
Network Port Interface
Two DS3 BNC coaxial connectors, Transmit and Receive
Line Code
B3ZS
Line Buildout
Short (0 to 100 ft.) or Long (100 to 450 ft.) of coaxial cable.
Electrical Compatibility
ANSI T1.404-1994
DS3 Framing Formats
ANSI T1.107-1995, M23 multiplex or C-bit parity
Transmit Timing Sources
Internal timing source: Stratum 4E (Local Oscillator)
External Timing: Recovered from the network
In-Service Performance
ANSI T1.231-1997 Digital Hierarchy
Physical Port
HSSI EIA/TIA 612 50-pin SCSI-2 connector
Compatibility
TIA/EIA 612, TIA/EIA 613
Data Rates
3 to 44.2 Mbps in 3 Mbps increments
Timing Source
Recovered from Network Timing
DS3 Monitoring: Cumulative errored seconds, P-bit errors, C-bit errors, FEBE errors.
Loopback Tests:
Line loopback, Payload Loopback, Local Loopback, Local Loopback with Self-Test, DTE
Loopback, Remote Lineloop, Remote Lineloop with Self-Test, Remote Payload Loopback
Remote Payload Loopback with Self-Test, End-to-End Self-Test
Power Dissipation
6.4 W maximum per slot, Load Number 1.1
Fusing
Two 2.5 A, 125V (GDC P/N 215-201-009)
One 5 A, 125V (GDC P/N 215-201-021)
Width: 178 mm (7.0 in.)
Height: 21 mm (0.81 in.)
Depth: 241 mm (9.5 in.)
Non-operating Temp.
-40 to 85 degrees C (-40 to 158 degrees F)
Operating Temp.
0 to 50 degrees C (32 to 122 degrees F)
(Derate by 1 degree C/1000 ft above sea level)
Operating Humidity
5% - 95% Relative humidity, non-condensing
Non-operating Altitude
0 m to 12,191 m (0 ft. to 40,000 ft.)
Operating Altitude
0 m to 3,047 m (0 ft. to 10,000 ft.)
SpectraComm 800 T3 Data Service Unit
Installation and Operation Manual
Technical Specifications
Weight: 0.28 kg (10 oz.)
Shipping weight: 0.74 kg (1 lb 10 oz)
076R160-000
Issue 4

Advertisement

Table of Contents
loading

Table of Contents