5.1.1.3. Receptacle
• The receptacle may be cleaned when it is outside the cabinet using a pressurised water
spray (max. 130 bar, temperature 40°C).
If using a rotating nozzle, make sure you do not damage the surface of the equipment,
which would make it increasingly difficult to clean over time.
• Dry very carefully with compressed air on all the surfaces, particularly the edges and
cavities.

5.1.2. Electro-pneumatic strip

• Clean with a cloth soaked in water. If there is heavy dirt, the front and the windows of the
air pressure indicators may be cleaned with a cloth soaked in water or non-aggressive,
non-greasy and non-flammable solvent. Do not use butyl-glycol.
In this case, make sure that the solvent does not come into contact with the electric but-
tons and lights, or with the pressure regulator buttons or with the front panel's metal sheet
• Dry by wiping with a dry cloth. While compressed air is not prohibited, it must only be used
at moderate pressure (max. 2 bars - 30 psi) on this part of the cabinet.

6. Maintenance

Detail
see RT Nr 6442
Replacement of the electro-pneu-
matic box fuse*
* Fuse characteristics: 10*38 500V 4A class gG.
Index revision : A
Preven-
Correc-
tive
tion
measure
Short circuiter 100 kV
21
Dura-
tion
X
5 mn
-
.
Frequency
7129