3. Characteristics

Footprint (W x H x P)
Mass
Maximum operating altitude
Min/max ambient temperature
Maximum relative humidity of 80% for
temperatures of up to 31°C, then linear
decrease until 50% relative humidity at
40°C
Operating voltage
Maximum current
Electrical power supply:
- Voltage
- Frequency
- Max. power consumption (50 VA
power supply module + generator)
Voltage surge
Compressed air pressure
Max. air flow
Product viscosity
Max. product flow
Products
(*) - The measurement of the viscosity of a water-soluble paint using a consistometric cup leads
to very significant errors. In effect, these paints are thixotropic: their viscosity decreases with the
intensity of agitation and with the time for which they are stirred. At rest, these paints are highly
viscous substances; in contrast, in movement, they become not very viscous substances. The
viscosities shown are indicative for paint stirred just before being measured with a cup.
(**) - Any other use is prohibited
Index revision : A
1100 x 1640 x 650
140 Kg
2,000 m
5°C - 40°C
Maximum of 80% without condensation
100 kV maximum
500 µA max.
Europe version
±
230 V
10%
50 -60 Hz
200 VA
Category II overvoltage according to standard IEC
61010-1:2010
±
7 bars (101 psi)
0.5 bars
Depends directly on the type of pump and the product
flow
Depends on the product used
According to the viscosity and the thixotropy of the
product (*) and according to the pump
Non-flammable paints with a resistivity that must be
between 1kΩ.cm and 250 kΩ.cm. (**).
WARNING : Not appropriate and also dangerous for
the solvent-based paints, resistive liquids and flamma-
ble liquids that form explosive atmospheres.
10
CSA Version
±
110V
10%
50 -60 Hz
200 VA
7129