4.3. Equipment to be connected by the user

WARNING : The connection of the equipment to the ISOCUBE cabinet by the user must conform
to standard NF EN 50348.

4.3.1. Generator connection

Electro-pneumatic box
Cable gland at the rear of the box
• Step 1: Run the power supply cable for the generator through a 1st cable gland, then con-
nect it to terminals X1.3 and X1.4
• Step 2: Run the generator cable through a second cable gland, then connect it to termi-
nals X1.5 and X1.6
4.3.2. Connection of the cabinet to the installation's general safety loop
• Step 1: Run the general safety loop cable
through one of the cable glands at the rear
of the box.
• Step 2: Replace the bridge between termi-
nals X2.1 and X2.2 by connecting a general
safety loop dry contact.
Index revision : A
Power supply cable
connection
Bridge
14
X1 terminal
Generator cable con-
nection
X2 terminal