4.3.5. Connection of the product regulator
• A product regulator control may be con-
nected to the "TR3" quick coupler D:4 at the
back of the electro-pneumatic box.
4.3.6. Connection of the high voltage
• Step 1: Run the generator's high voltage
cable through the cable gland in the top
left.
• Step 2: Connect the generator's high
voltage cable to the body of the pump at
the link for all the equipotential links.
• Step 3: Connect the high voltage cable
present in the Isocube cabinet from the
short-circuiter to the body of the pump at
the link for all the equipotential links.
• Step 4: Connect the paint points to the
pump body at the link for all the equipoten-
tial links using an equipotential wire and the
alligator clamp provided.