1. Health and safety instructions

This document contains links to the following operation manuals:
see RT Nr 6442
see RT Nr 6440
See leaflet ref: 573 303 050

1.1. Marking

1.2. Simplified analysis of the potential sources of electric shocks

When non-flammable products (defined in standard NF EN 50348 appendix A) are used, the
inflammation risk is by definition zero. However, these products contain large quantities of water
which quickly store enough quantities of energy to cause electric shocks.
That is why the ISOCUBE insulating cabinet is equipped with systems to prevent this type of risk.
Potential source of elec-
tric shock
Voluntary or involuntary
contact with the pump or
the paint drum
Voluntary or involuntary
contact with the sprayer
injector
Incorrect earthing
Index revision : A
for the 100 kV short-circuiter.
for the installation guide for flammable conductor paint antenna.
for the stirrer (option).
3
Registered Design
Automatic earthing of all parts
under HV if the door is opened
Limitation of the length of the
product hose to 18 m max and
the capacity of the product
drum to maximum 60 l.
Prohibition of spraying of prod-
ucts with a resistivity below 1000
Ω.cm.
The equipment must be earthed
by means of at least 2 points: its
electrical supply and a dedi-
cated wire (supplied)
Measures
4
Means applied
Time to implementation of
security measures of less
than 2 sec
60l max for all the contain-
ers which must be con-
ductors and connected to
the equipotential connec-
tion (supplied)
The operator must periodi-
cally check the quality of
the earthing outlets
7129