4
Identification of the product
4.1
Description of FSTART Gravity
Guns recommended to spray varnishes, lacquers, shades, polyurethanes.
4.2
Description of the ATEX marking
•
Each device is marked with the name of the manufacturer, the reference of
the device and important information for the use of the device (air pressure,
electrical power, etc.).
•
This equipment has been designed in accordance with the ATEX Directive
2014/34/EU and is intended for use in Zone 1.
SAMES KREMLIN
FRANCE
CE
II 2 G
Ex h IIB T6 X
Gb
20xx
FSTART
Type xx
P air : 6 bar / 87 psi
Name and address of the manufacturer
CE: European conformity:
area
II: group II
2: class 2 G: gas
Surface equipment meant to an area where
explosive atmospheres due to gas, vapours, mists
are liable to appear from time to time in usual
operating.
Ex :
Marking of conformity with European standards
h :
Mode of protection for non-electrical device
IIB :
Gas group
T6 :
Temperature class
- Maximum surface temperature : 85°C / 185° F
X :
Special conditions that apply for a safe use.
Refer to instructions listed in the instruction manuals
accompanying your purchase.
Gb :
Equipment protection level (Gas zone1)
Marking of the manufacturing year (with 4
characters)
Gun model
Gun air supply maximum pressure
for use in explosive
8