4. CONFIGURATION

4.13.1. STP.xx - Value of step xx

Acronym
STP.xx
CUSTOM LINEARIZATION STEP
The parameter shows and sets the value of the various steps, with xx from 0 to 32.
The low scale value goes in STP.00 and the full-scale value in STP.32.
The value of the nth step corresponds to the input: mV start scale + n*ΔmV con ΔmV = (mV full scale - mV start scale)/32.
Unit of measurement:
Options:
-1999...9999

4.13.2. MV.STA - Setting mV at start of scale

Acronym
MV.STA
MV START SCALE
The parameter shows and sets the value in millivolts at start of scale if the input is a thermocouple.
Unit of measurement:
Options:
-19.99...99.99

4.13.3. MV.FUL - Setting mV at full scale

Acronym
MV.FUL
MV FULL SCALE
The parameter shows and sets the value in millivolts at full scale if the input is a thermocouple.
Unit of measurement:
Options:
MV.STA + 1...99.99
4.13.4. MV.50C - Setting mV at temperature of 50 °C
Acronym
MV.50C
MV AT 50 'C
The parameter shows and sets the value in millivolts at 50°C if the input is a thermocouple.
Unit of measurement:
Options:
-1.999...9.999
Scrolling message
Scale points
Scrolling message
mV
Scrolling message
mV
Scrolling message
mV
80224_MHW_650 L - 1250 L_07-2018_ENG - 66
Submenu
Attributes
LINRZ
R W
Submenu
Attributes
LINRZ
R W
Submenu
Attributes
LINRZ
R W
Submenu
Attributes
LINRZ
R W