Power Supply; Inputs; Outputs - gefran 650 L Installation And Instruction Manual

Alarm limit indicator
Table of Contents

Advertisement

2.3.2.

Power supply

Powe supply
6
5
4
22
~
23
PWR
~
24
2.3.3.

Inputs

TC Input
6
5
4
3
+
2
1
-
Linear input (V, I)
6
5
4
3
+
2
1
-
Linear input (V)
6 5
+
4
3
2
1
-
Input PT100/JPT100 - 2-wires connection
6
5
4
3
T
2
1
Standard: 100...240VAC/VDC ± 10%
50/60Hz, max 5 VA
Optional: 20...27VAC/VDC ± 10%
50/60Hz, max 5 VA
Available thermocouples:
J, K, R, S,T, C, D, B, E, L, U, G, N,
Pt20Rh-Pt40Rh
ITS90 or custom linearization
Maintain polarity
For extensions, use a compensated
cable suitable for the type of TC used
linear input voltage
60 mV (Ri > 70kΩ
1 V (Ri > 15kΩ
Linear input in direct current
0/4...20mA, Ri = 50 Ω.
Linear input in direct voltage
5 V, 10V (Ri > 30kΩ
Attention:
with this type of connection the line resi-
stance can introduce measurement error,
we recommend that you use wires of ade-
quate cross-section.
The resistance of the three wires must be
equal, and less than 20 ohm.
80224_MHW_650 L - 1250 L_07-2018_ENG - 17
Input PT100/JPT100 - 3-wires connection
6
5
4
3
T
2
1
2.3.4.

Outputs

Type of outputs are specified when the indicator is ordered.
Output Out 1 – 5 A relay
NO
6
5
C
4
3
2
Output Out 2 - 5A relay
NO
19
20
C
21
22
23
24
Output Out 3 - 5A relay
19
20
NO
21
22
C
23
24
2. INSTALLATION
Attention:
with this type of connection the line resi-
stance can introduce measurement error,
we recommend that you use wires of ade-
quate cross-section.
The resistance of the three wires must be
equal, and less than 20 ohm.
5 A
Relay
250
VAC
5 A
Relay
250
VAC
5 A
Relay
250
VAC

Advertisement

Table of Contents
loading

This manual is also suitable for:

1250 l

Table of Contents