Information on displays and use of keys

The general description of the displays and keys for each
model is in paragraphs "1.3.1. Display and keys 650 L" on
page 8, "1.4.1. Display and keys 1250 L" on page 10.
3.1.1.

Menu navigation

4 keys are used for navigating the menus and submenus and
for changing parameters and confirming choices.
Their function depends on the context and on how long they
are pressed.
The LEDs above the keys not only give confirmation
that each key has been pressed (by flashing), but
also show which keys can be used in each situa-
tion.
The navigation functions assigned to the keys are:
At first power-on, scrolls the fast configuration
menu; otherwise, the user configuration menu
(Alarm limits, etc.).
Each time you press the key, the value of the
displayed parameter is confirmed and you go to the
next menu item.
Keep the key pressed for more than 2 seconds to
enter the Programming/Configuration menu.
Each time you press the key, you return to the pre-
R
vious menu item or to the higher menu level, as ap-
propriate.
Keep the key pressed for more than 2 seconds to
return to the Main menu.
Alarm RESET holding down the key for 3 seconds
Press the key to enter a submenu or to reduce the
value of the displayed parameter, as appropriate.
Keep the key pressed to progressively increase the
speed of reduction of the displayed parameter
Press the key to raise the value of the displayed
parameter.
Keep the key pressed to progressively increase the
speed of raising the displayed parameter.
3.

COMMISSIONING

80224_MHW_650 L - 1250 L_07-2018_ENG - 23
3.1.2.

Displays

The indicators have 2 or 3 displays, depending on the model.
The Main menu shows:
PV display: value of process variable.
SV display: value of parameter (Alarm 1 limit).
F Display (models 1250 L only): value of control output
(if parameter dS.F = OUT.PW).
On models 1250 L, the percentage value of the control
output is also shown graphically on a bargraph.
According to the situation (programming, alarm, etc.), the
indicator displays can show other information, such as the
name of the parameter, description of the parameter, diagno-
stics messages and alarm messages.
Attention! The displays show only the parameters
and menus for a defined configuration.
3.1.2.1.

Display characters

The displays reproduce the various characters by combining
7 or 14 segments.
The following tables show the shape of the various cha-
racters.
!
"
#
*
+
,
-
4
5
6
7
>
?
@
A
H
I
J
K
R
S
T
U
\
]
^
_
f
g
h
i
p
q
r
s
z
|
˜
Figure 12 - 14-segment font
3. COMMISSIONING
$
%
&
'
(
.
/
0
1
2
8
9
:
;
<
B
C
D
E
F
L
M
N
O
P
V
W
X
Y
Z
`
a
b
c
d
j
k
l
m
n
t
u
v
w
x
)
3
=
G
Q
[
e
o
y