COMMISSIONING AND MAINTENANCE
3.3

Error List

When a display has a technical fault, a numeric error code ap-
pears that will enable the maintenance operator to identify the
possible cause.
There are 3 categories of errors:
1
Permanent: errors that require a manual reset
2
Temporary: errors that are automatically reset once the
cause that generated them is removed or stopped
3
Notices: simple warnings that do not block the appliance's
operation
3.3.1

Permanent Errors

Nr.
Error
0
E2PROM_READ_ERROR
1
IGNIT_ERROR
2
GV_RELAY_ERROR
3
SAFETY_RELAY_ERROR
4
BLOCKING_TOO_LONG
FAN_ERROR_NOT_RUN-
5
NING
6
FAN_ERROR_TOO_SLOW
7
FAN_ERROR_TOO_FAST
8
RAM_ERROR
WRONG_EEPROM_SIG-
9
NATURE
10
E2PROM_ERROR
11
STATE_ERROR
12
ROM_ERROR
15
MAX_TEMP_ERROR
16
FLUE_GAS_ERROR
17
STACK_ERROR
18
INSTRUCTION_ERROR
19
ION_CHECK_FAILED
20
FLAME_OUT_TOO_LATE
21
FLAME_BEFORE_IGNIT
23
CORRUPTED_ERROR_NR
29
PSM_ERROR
30
REGISTER_ERROR
Description
Internal software error
Three unsuccessful ignition
attempts in a row
Failure detected in the GV
relay
Failure detected in safety
relay
Control had a blocking error
for more than 20 hours
Fan is not running for more
than 60 seconds
Fan runs too slow for more
than 60 seconds
Fan runs too fast for more
than 60 seconds
Internal software error
Contents of Eeprom is not up
to date
Wrong safety parameters in
Eeprom
Internal software error
Internal software error
The external overheat pro-
tection is enabled or the
T_Supply sensor measures
a temperature of over 100°C
(212°F)
Flue temperature exceeded
the maximum flue temper-
ature
Internal software error
Internal software error
Internal software error
Flame still present 10 seconds
after closing the gas valve
Flame is detected before
ignition
Error code RAM byte was cor-
rupted to an unknown error
code
Internal software error
Internal software error
3.3.2

Temporary Errors

Nr.
Error
100
WD_ERROR_RAM
101
WD_ERROR_ROM
102
WD_ERROR_STACK
WD_ERROR_REG-
103
ISTER
REFHI_TOO_HIGH /
106
REFHI_TOO_LOW
REFHI_TOO_HIGH /
107
REFHI_TOO_LOW
REFHI_TOO_HIGH /
108
REFHI_TOO_LOW
REFHI_TOO_HIGH /
109
REFHI_TOO_LOW
REFHI_TOO_HIGH /
110
REFHI_TOO_LOW
REFHI_TOO_HIGH /
111
REFHI_TOO_LOW
REFHI_TOO_HIGH /
112
REFHI_TOO_LOW
REFHI_TOO_HIGH /
113
REFHI_TOO_LOW
114
FALSE_FLAME
LOW_WATER_PRES-
115
SURE_ERROR
118
WD_COMM_ERROR
119
RETURN_OPEN
120
SUPPLY_OPEN
122
DHW_OPEN
123
FLUE_OPEN
126
RETURN_SHORTED
127
SUPPLY_SHORTED
129
DHW_SHORTED
130
FLUE_SHORTED
133
Net Freq Error
RESET_BUTTON_ER-
134
ROR
163
T_SELECTION1_OPEN Heat exchanger's flow rate too low
3.3.3

Warnings

Nr.
Error
Description
CC_LOSS_
Cascade system: the burner of the man-
200
COMMUNI-
aging module has lost the signal of one of
CATION
the depending thermal module burner
CC_LOSS_
Cascade system: the managing module
201
COMMUNI-
has lost the signal of one of the depend-
CATION
ing thermal module
OUTDOOR_
202
Outdoor sensor is open of shorted
WRONG
T_SYSTEM_
203
T_System sensor is open of shorted
WRONG
T_CASCADE_
204
T_Cascade sensor is open of shorted
WRONG
58
Description
Internal software error
Internal software error
Internal software error
Internal software error
Internal software error
Internal software error
Internal software error
Internal software error
Internal software error
Internal software error
Internal software error
Internal software error
Flame is detected in a state in
which no flame is allowed to be
seen.
Low water pressure error
Watchdog communication error
Return sensor open
Supply sensor open
DHW sensor open
Flue sensor open
Return sensor shorted
Supply sensor shorted
DHW sensor shorted
Flue sensor shorted
Net. freq. error detected by the
watchdog
Too many resets in a short time
period