3.5

Adjustments

The thermal module Condexa PRO is supplied for operation with
G20 (methane gas), as indicated by the type plate, and has al-
ready been factory-calibrated by the manufacturer.
However, if it is necessary to repeat the adjustments, for exam-
ple after non-scheduled maintenance, replacing the gas valve
or after transformation from G20 gas to G30-G31 gas, or vice ver-
sa, proceed as described below.
9
Adjustments to maximum and minimum power must be
performed in the indicated sequence and only by Technical
Assistance Service.
Before making the regulation:
− remove the locking screw
− pull the front panel outwards and then to the top to de-
couple it from points A.
CO2 ADJUSTMENT AT MAXIMUM POWER
− Press the MENU key, select "System test" and press ● to
confirm.
Menu
"
"
Domestic Hot Water (DHW)
"
Information
"
"
Settings
"
"
System Test
"
"
− select "Max. power" with the ▲ / ▼ keys and press ● to
confirm. The fan starts turning at its maximum speed
(which can vary based on the model).
System Test
"
"
Test State
"
"
Fan Speed
"
"
Ionisation
"
"
A
A
"
High Power
"
0
rpm
"
"
0.0 μA
− the appliance will operate at maximum power.
− unscrew the cap (1) and insert the combustion analyser
sensor
− set the CO2 with a screwdriver on the regulation screw (2)
placed on the gas valve, thus reaching the value reported
on the table.
CO2% maximum power
Condexa PRO 35 P
Condexa PRO 50 P
Condexa PRO 57 P
Condexa PRO 70 P
Condexa PRO 90
Condexa PRO 100
Condexa PRO 115
Condexa PRO 135
CO2 ADJUSTMENT AT MINIMUM POWER
System Test
"
"
Test State
"
"
Fan Speed
"
"
Ionisation
"
"
− the appliance will operate at minimum power.
− Adjust the CO2 using a screwdriver on the adjustment
screw (3) on the fan unit, so as to obtain a value listed
in the table.
CO2% minimum power
Condexa PRO 35 P
Condexa PRO 50 P
Condexa PRO 57 P
Condexa PRO 70 P
Condexa PRO 90
Condexa PRO 100
Condexa PRO 115
Condexa PRO 135
Versions Condexa PRO 35 P - Condexa PRO 70 P
"
61
COMMISSIONING AND MAINTENANCE
Gas type
G20 - G25
9 - 9
9 - 9
9 - 9
9 - 9
9 - 9
9 - 9
9 - 9
9 - 9
Gas type
G20 - G25
9 - 9
9 - 9
9 - 9
9 - 9
9 - 9
9 - 9
9 - 9
9 - 9
+
CO
CO
2
2
1
3
2
3
2
G30 - G31
10,4 - 9,9
10,4 - 9,9
10,4 - 10,4
10,4 - 10,4
10,4 - 10,4
10,4 - 10,4
10,4 - 10,4
10,4 - 10,4
Low Power
"
"
0
rpm
"
"
0.0 μA
G30 - G31
10,4 - 9,9
10,4 - 9,9
10,4 - 10,4
10,4 - 10,4
10,4 - 10,4
10,4 - 10,4
10,4 - 10,4
10,4 - 10,4
+