N3601 Imager Engine Reading Distances

The depth of field measurements were taken using these parameters:
Note: Time to Read and Depth of Field are impacted if the bar code symbol is at the edge of
the image.
Guaranteed Specs
Focus
Symbology
100% UPC-A
5 mil Code 39
10 mil Code 39
20 mil Code 39
15mil Code 128
6.7 mil PDF 417
15 mil QR
Typical Specs
Focus
Symbology
100% UPC-A
5 mil Code 39
10 mil Code 39
20 mil Code 39
15mil Code 128
6.7 mil PDF 417
15 mil QR
82
Distances are measured from the top of the engine to the bar code
23 °C (+73 °F), 10K lux
Clear, High quality bar codes
Standard Range (SR)
Near Distance
Far Distance
(in/cm)
(in/cm)
2.4 (6.2)
18.5 (47.0)
3.1 (9.7)
6.9 (17.6)
1.2 (3.1)
17.9 (45.5)
2.6 (6.5)
25.8 (63.0)
2.4 (6.0)
23.6 (60.0)
2.5 (6.3)
8.0 (19.0)
2.4 (6.0)
10.6 (27.0)
Standard Range (SR)
Near Distance
Far Distance
(in/cm)
(in/cm)
2.4 (6.0)
20.5 (52.0)
3.0 (7.5)
7.4 (18.9)
1.2 (3.1)
17.9 (45.5)
2.6 (6.5)
25.8 (63.0)
2.4 (6.0)
23.6 (60.0)
2.5 (6.3)
8.0 (19.0)
2.0 (5.0)
12 (28.0)
Delta
(in/cm)
16.1 (40.8)
3.8 (10.8)
16.7 (42.4)
23.2 (56.5)
21.2 (58.6)
5.5 (12.7)
8.2 (21.0)
Delta
(in/cm)
18.1 (46.0)
4.4 (11.4)
16.7 (42.4)
23.2 (56.5)
21.2 (58.6)
5.5 (12.7)
10 (23.0)