Ea30 Scan Engine - Honeywell CN70 Series Service Work Instructions

Hide thumbs Also See for CN70 Series:
Table of Contents

Advertisement

TITLE
CN70 Service Work Instructions

EA30 Scan Engine

OPERATION:
The EA30 scan engine is located on the scan bracket assembly. To service the scan engine you will need to remove
the scan bracket assembly.
Tools Required
Description
T10 Torx driver
T7 Torx driver
Phillips screwdriver with #0 tip
Parts Required
Item Part Number
1
3-143010-03
2
800-450-001
3
234-008-0100
4
906-016-002
5
655-289-001
6
655-223-001
7
655-360-001
Removal
1. Remove the bottom housing assembly (refer to Bottom Housing operation).
2. Remove the scan bracket assembly (refer to Scan Bracket Assembly operation).
Continued on next page...
Description
EA30 Scan Engine
Thd Form Screw,M1.7 x 4mm Flat Hd RoHS
FLEX ASSY, KELLER SCANNER, COZ
Kapton tape (use .3 inches)
Kapton tape
Foam pad
Tape,Foil Gnd ea 30 CN70 (Used on Southwest Airline CN70)
7
Model
CN70A,CN70E
Part Number
2
1
4
5
DOCUMENT NO.
SWICN70-000
Page 37 of 45
Qty
1
2
1
1
1
1
1
3
6