Imager Reading Distances - Honeywell Dolphin CT50 User Manual

Powered by windows 10 iot mobile enterprise
Hide thumbs Also See for Dolphin CT50:
Table of Contents

Advertisement

Postal Codes

Imager Reading Distances

The guaranteed depth of field measurements were taken using these parameters:
Note:
Time to Read and Depth of Field are impacted if the bar code symbol is at the edge of the image.
White Illumination Monochrome Sensor Only - Guaranteed Specs
Focus
Symbology
5 mil Code 39/128
10 mil Code 39/128
100% UPC
6.7 mil PDF 417
10 mil DataMatrix/Aztec
White Illumination Monochrome Sensor Only - Typical Specs
Focus
Symbology
5 mil Code 39/128
10 mil Code 39/128
100% UPC
6.7 mil PDF 417
10 mil DataMatrix/Aztec
60
Australian Post
Canadian Post
KIX (Netherlands Dutch) Post
Japanese Post
British Post
Planet Code
Postnet
UsIntelligent
Distances are measured from the front of the engine.
23 °C (73 °F), 0 lux
Photographic quality codes
Standard Range (SR)
Near Distance
Far Distance
(in/cm)
(in/cm)
3.6 (9.1)
5.6 (14.2)
1.9 (4.8)
12.0 (30.5)
2.1 (5.3)
15.1 (38.1)
2.5 (6.4)
6.6 (16.7)
2.9 (7.4)
7.3 (18.5)
Standard Range (SR)
Near Distance
Far Distance
(in/cm)
(in/cm)
2.5 (6.4)
6.4 (16.3)
1.1 (2.8)
13.0 (33.0)
1.8 (4.6)
16.5 (41.9)
1.8 (4.6)
7.3 (18.5)
2.1 (5.3)
8.0 (20.3)
Dolphin CT50 with Windows 10 IoT User Guide
Delta
(in/cm)
2.0 (5.1)
10.1 (25.6)
12.9 (32.7)
4.1 (10.4)
4.4 (11.1)
Delta
(in/cm)
3.9 (9.9)
11.9 (30.2)
14.7 (37.3)
5.5 (14.0)
5.9 (15.0)

Advertisement

Table of Contents
loading

Table of Contents