DCIP 600-... system-free up to
4 users with DCA 740-01
Functional characteristics
Up to 4 PC users (Software Clients)
of a network can be called from the
door station, with a direct connected
button module e.g. TM 612-4.
Calling, speech and door release via
the Software Client DCIP SC 600-... .
The Software Client must be
installed on every PC which
receives door calls. Door calls are
additionally routed to the analogue
PBX extension of a telephone
system. This task is assumed by the
DCA 740-... The video image is still
displayed through the Software
Client and all control functions
such as the door release are also
performed via the PC. The speech
connection is established via the
DCA 740-... and the telephone
system.
Standard call tones for the Software
Client 3-tone chime. A dedicated
*.wav file can be assigned for each
call tone.
It is not possible to listen in to an
existing call from other PC users in
the network.
The door is opened by the called
PC user using a "virtual door
release button", the light switching
function is actuated using a "virtual
light button". The door call can be
muted with an optical display on the
monitor.
Supplementary functions
• With additional TME 645-... units,
up to 49 users are possible.
• Connection of the COM 611-... is
possible in order to call a maximum
of 49 PC users by means of code
selection.
• Up to 25 PC users can be called in
parallel with a call button from the
door station.
• Every PC user to which a door
call has been established occupies
currently 2 registrations in the IPVS.
Remarks
a) Door release 12 V AC, use at least
20 Ohm (e.g. TÖ 615-...)
b) The NG 600-0 can also take
over the power supply to existing
on-site call buttons. A voltage of
12 V AC max. 200 mA is available
for the lighting if a door release
with an impedance of at least
20 Ohm is used. With a higher
current consumption, an additional
transformer must be used.
• 12 V AC consumers in the wiring
diagram:
• Door release appr. 600 mA
Camera heating appr. 100 mA
• Door release contact load in the
SIVS 600-... max. 24 V AC, 1 A
• Light contact load in the door
loudspeaker max. 24 V AC, 2 A
c) Distance of the SIVS 600-... to the
door station max. 200 m with
J-Y(ST)Y 0.8 mm core material.
Distance between the two devices
SIVS 600-... and IPVS 600-... in the
distributor max. 1 m.
During installation, ensure that the
door release is laid in a separate
cable.
Power supply to the SIVS 600 15 V
DC (terminal bv+/cv-), max. 300 mA.
d) ***Optionally the DCA 740-01
can be connected to the PBX
extension of a telephone system.
Active door calls can then be routed
via the telephone.
The functional features of the
software client can still be used.