SSS Siedle AIB 150 series System Manual

SSS Siedle AIB 150 series System Manual

In-home bus: audio. plug+play
Hide thumbs Also See for AIB 150 series:
Table of Contents

Advertisement

System Manual
In-Home bus: Audio
Issue 2017

Advertisement

Table of Contents
loading

Summary of Contents for SSS Siedle AIB 150 series

  • Page 1 System Manual In-Home bus: Audio Issue 2017...
  • Page 2: Table Of Contents

    Contents 1 In-Home bus: Audio 7 Programming 8 Supplementary functions System description Overview of functions Switching and control functions 2 Siedle Systemtechnik Remarks Door release actuation Jung indoor stations 7.1 Programming – manual Parallel door call 3 Safety remarks Activating the bus line rectifier Storey call parallel switching Danger Activating the bus...
  • Page 3: In-Home Bus: Audio System Description

    1 In-Home bus: Audio 2 Siedle Systemtechnik 3 Safety remarks System description Jung indoor stations Danger Configuration “Single line“ “Siedle Systemtechnik” and the The In-Home bus: The Audio system relevant logo are used to describe comprises a bus installation with devices, components or systems a two-core line permitting the which are not manufactured...
  • Page 4: Configuration, Conductor Lengths

    4 Configuration, conductor lengths User assignment Devices occupying 1 user AIB 150-… BTS 850-… BTC 850-… BFC 850-… BNS 750-… BSE 650-… BEM 650-… BSM 650-… Devices occupying 2 users BTLM 650-… CL A xx B-02 STL … BTLE 050-… Devices with variable user assignment (depending on programming) DCA 650-… Devices occupying no users BNG 650-… VNG 602-…...
  • Page 5: Single Line System

    Single line system Configuration of In-Home: Audio Conductor length The basic installation of Conductor material J-Y(ST)Y In-Home-Bus: Audio takes place as or YR conductor with 0.8 mm a single-line system. Within this line, diameter: the users are installed on the bus •...
  • Page 6 4 Configuration, conductor lengths Single line system Range Side Side Cable material J-Y(ST)Y or circuit 1 circuit 2 YR 0.8 mm Distribution of the installation in the sub-distribution board: • Range to door station 1 and door station 2 Each max. 300 m, •...
  • Page 7: Single-Line System With Intercom

    Single-line system with intercom functions Configuration with intercom Conductor material function Telecommunication or light current Using the handsfree bus telephone conductors can be used for instal- BFC 850-…, internal building com- lation: munication can be supplemented J-Y(St)Y Twisted pair conductors, to include additional convenience shielded functions.
  • Page 8: Multiple Line System

    4 Configuration, conductor lengths Multiple line system Line 1 Line 2 Line 15 Most distant BNG-BNG (Sa/Sb) connection max. 300 m/984 ft.
  • Page 9 Configuration of the multiple line system A multiple line system comprises individual lines which are linked together by two cores. The lines are connected at the bus line rectifier using terminals Sa and Sb. In mul- tiple line systems, door calls and control functions are possible from one line to another.
  • Page 10: In-Home: Audio Users

    5 In-Home: Audio users Door loudspeakers, call buttons BTLM 650-04 BTM 650-01 to -04 DRM 612-01 Bus door loudspeaker module for Bus call button modules for In-Home Display call module as an input In-Home bus. Loudspeaker and bus 1–4 call buttons, integrated LED device with 4-line display for placing microphone integrated, illuminated lighting.
  • Page 11 Siedle Classic Siedle Steel Door station with stainless steel Door station with stainless steel front. Door loudspeaker and illu- front, door loudspeaker and call but- minated call buttons. Integrated tons. Integrated door release contact door release contact (TÖ), contact (TÖ), contact load max. 15 V AC, load max. 15 V AC, 30 V DC, 2A, 30 V DC, 2 A, switching time TÖ...
  • Page 12: Power Supply, Line Rectifiers

    5 In-Home: Audio users Power supply, line rectifiers BNG 650-0 ZBVG 650-0 NG 602-01 Bus line rectifier in a 9-grid housing. Bus supply unit accessory as a Line rectifier in switch panel housing Primary: 230 V AC, 50/60 Hz plug-in card for integration in bus for 1+n technology, and for power Secondary: 12 V AC, 1 A line rectifier BNG 650-…...
  • Page 13: Switching, Control

    Switching, control BSM 650-02 BSE 650-01 BEM 650-01 Bus switching module in 3-grid Bus switching unit with bistable Bus input module for mounting in housing. 4 integrated relays, each relay, suitable for mounting in a 70 a 70 junction box with an input for with a potential-free working con- junction box.
  • Page 14: Doorcom

    5 In-Home: Audio users Software, PC interface, DoorCom PRI 602-0 PRI 602-01 USB BPS 650-… from V2.50 Programming interface for con- Programming interface for con- Bus programming software for nection of a Windows PC via serial nection of a Windows PC via USB programming In-Home bus systems.
  • Page 15: Bus Indoor Devices

    Bus indoor devices AIB 150-01 BTS 850-02 BTC 850-02 Audio indoor station Siedle Basic: Standard bus telephone. Connection Deluxe bus telephone. Connection Handsfree station for surface at bus cores Ta and Tb. at bus cores Ta and Tb. mounting. Functions: Functions: Entry-level device with all essen- •...
  • Page 16 5 In-Home: Audio users Bus indoor devices BFC 850-0 BNS 750-02 Deluxe handsfree bus telephone Bus secondary signal unit, for intercom. Connection at bus cores signalling door and storey door Ta and Tb. calls in another room or corridor. Functions: Connection to In-Home bus: Audio •...
  • Page 17: Jung Indoor Stations

    Jung indoor stations SI 4 A .. SI AM … Audio indoor station standard The audio module is the basic Audio indoor station design standard module of the modular structured Calling, speech, door release, light, flush mounted indoor station. This storey call, switching/control func- is where the Siedle In-Home bus is tions and internal communication.
  • Page 18: Accessories

    5 In-Home: Audio users Accessories ZTS 800-01 ZTC 800-0 ZPS 850-0 Table-top accessory for telephones Deluxe table-top accessory for the Parallel switching accessory for BTS/BFC 850-… and HTS 811-… for bus telephone BTC 850-… for con- integration into deluxe bus tele- conversion from a wall to a table-top version from a wall to a table top phone BTC 850-…...
  • Page 19 ZPSF 850-0 ZAR 850-0 ZARF 850-0 Parallel switching accessory for inte- Interfacing relay accessory for inte- Handsfree interfacing relay accessory gration into deluxe handsfree bus gration into bus telephone BTS/ for integration in the handsfree bus telephone BFC 850-… Circuit board BTC 850-…...
  • Page 20: Installation General Information

    6 Installation General information Note Consumers Voltage Current As in the as-delivered/de-energized Door release 12 V AC appr. 600 mA status, the contact position of the bistable relay (contact S1/S1) cannot Vario bus call button module 12 V AC max. 20 mA be defined, the bus supply to the (BTM 650-01 to -04) device must be connected before-...
  • Page 21: Bus Call Button Module, Bus Line Rectifier

    Bus call button module, bus line rectifier Bus call button module Connection of the bus call button BTLM 650-04 BTLM 650-04 modules to the bus door loud- speaker via ribbon cable. The name plate lighting is supplied from the terminal block of the BTLM 650-04. If there are more than 20 illuminated In-Home-Bus In-Home-Bus...
  • Page 22: Modular Jung Indoor Station

    6 Installation Modular Jung indoor station Every module is mounted in a flush-mounting junction box in compliance with DIN 49073. We rec- ommend using a deep junction box SI VM ... for mounting. Mounting takes place using the provided support rings. Mounting can take place in combi- nation or individually –...
  • Page 23 Audio combinations Item no. Item designation SI AM … Audio module SI TM .. 5073 Standard call button module SI AM … Audio module SI TM .. 5093 Universal call button module SI AM … Audio module SI TM .. 5093 Universal call button module SI TM .. 5073 Standard call button module SI AM … Audio module SI TM .. 5093 Universal call button module SI TM .. 5093 Universal call button module...
  • Page 24: 6.1 Installation Audio

    6.1 Installation audio Siedle Vario...
  • Page 25 Siedle Vario Supplementary functions Remarks • Internal speech communication a) The BNG 650-… is able to supply Functional between bus indoor devices is only 1 door release and max. 20 bus call Calling and speech between the possible internally within the same button modules with LED lighting door station and the connected bus line.
  • Page 26: Siedle Custom-Fit Door Loudspeaker

    6.1 Installation audio Siedle custom-fit door loudspeaker...
  • Page 27 Siedle custom-fit door loud- Supplementary functions Remarks speaker • Internal speech communication a) The BNG 650-… can also supply between bus indoor devices is only the customer’s own existing call Functional possible internally within the same buttons. A voltage of 12 V AC Calling and speech between the line.
  • Page 28: Siedle Classic

    6.1 Installation audio Siedle Classic...
  • Page 29 Siedle Classic Supplementary functions Remarks • Internal speech communication a) The BNG 650-… can supply 1 Functional between bus indoor devices is only door release and a maximum of Calling and speech between the possible internally within the same 80 buttons. With more than 80 call door station and the connected bus line.
  • Page 30: Siedle Steel

    6.1 Installation audio Siedle Steel...
  • Page 31 Siedle Steel Supplementary functions Remarks • Internal speech communication a) The BNG 650-… can supply Functional between bus indoor devices is only 1 door release and a maximum Calling and speech between the possible internally within the same of 130 buttons. With more than door station and the connected bus line.
  • Page 32 6.1 Installation audio Siedle Vario with Intercom functions...
  • Page 33: Siedle Vario With Intercom

    Siedle Vario with Basic functions with all bus Remarks Intercom functions indoor devices a) The BNG 650-… is able to supply • Internal speech communication 1 door release and max. 20 bus call Functional between bus indoor devices is only button modules with LED lighting Calling and speech between the possible internally within the same BTM 650-01, -02, -03 and -04.
  • Page 34: Siedle Vario 2 Door Stations

    6.1 Installation audio Siedle Vario 2 door stations...
  • Page 35 Siedle Vario 2 door stations Supplementary functions Remarks • Internal speech communication a) The BNG 650-… is able to supply Functional between bus indoor devices is only 1 door release and max. 20 bus call Calling and speech between the possible internally within the same button modules with LED lighting door station and the connected bus line.
  • Page 36: Multiple Line System

    6.1 Installation Multiple line system...
  • Page 37 Multiple line system Supplementary functions Remarks • Internal speech communication a) The BNG 650-… is able to supply Functional between bus indoor devices is only 1 door release and max. 20 bus call Calling and speech between the possible internally within the same button modules with LED lighting door station and the connected bus line.
  • Page 38: Call Via Display Call Module

    6.1 Installation audio Call via display call module...
  • Page 39 Call via display call module Supplementary functions Remarks • Internal speech communication a) The BNG 650-… is able to supply Functional between bus indoor devices is only 1 door release and max. 20 bus call Calling and speech between the possible internally within the same button modules with LED lighting door station and the connected bus line.
  • Page 40: Doorcom Analog Dca 650

    6.1 Installation audio DoorCom Analog DCA 650-…...
  • Page 41: Doorcom Analog Dca 650

    DoorCom Analog DCA 650-… Remarks a) The BNG 650-… is able to supply Functional 1 door release and max. 20 bus call Calling and speech between the button modules with LED lighting door station and the connected a/b BTM 650-01, -02, -03 and -04. telephones of a telephone system.
  • Page 42: 6.2 Siedle Systemtechnik Installation

    6.2 Siedle Systemtechnik installation Jung audio indoor station...
  • Page 43 Jung audio indoor station Supplementary functions Remarks Calling and speech between door • Internal speech communication a) The BNG 650-… is able to supply stations and the connected Jung between bus indoor devices is only 1 door release and max. 20 bus call indoor devices.
  • Page 44 6.2 Siedle Systemtechnik installation Siedle and Jung indoor stations combined...
  • Page 45: Siedle And Jung Indoor Stations

    Siedle and Jung indoor stations Supplementary functions Remarks combined • Internal speech communication a) The BNG 650-… is able to supply Calling and speech between door between bus indoor devices is only 1 door release and max. 20 bus call stations and the connected Jung possible internally within the same button modules with LED lighting indoor devices.
  • Page 46: Programming

    7 Programming Overview of functions Functions with Siedle In-Home and not available programming possibilities. Terms •/-/- Plug+Play programming used in the table are explained in -/•/- Manual programming detail on the next page. -/-/• PC programming Basic functions Door call •/•/•...
  • Page 47 Basic functions Door call •/•/• •/•/• -Storey call -Door release button -Light button -Call silencing and display (Functional following installation) Dialling last door -/-/• -/-/• (Functional following installation) Call tone configuration -/•/• -/•/• Setting at the bus indoor device Supplementary functions BSE Groups -/-/•...
  • Page 48 7 Programming Overview of functions Dialling last door Internal call Call tone configuration The door station from which the last Bus indoor devices can place calls to At each bus indoor device, different door call was placed can be dialled each other using the buttons.
  • Page 49 Door dialling One or more door stations can be selectively dialled and a speech con- nection established. Doormatic The door release contact in the bus video line rectifier and in the calling bus door loudspeaker switches for 3 seconds after the door bell button has been pressed.
  • Page 50: Remarks

    7 Programming Remarks The In-Home bus can be pro- • In multiple line systems bus power grammed in three ways: supply accessory ZBVG 650-… must be additionally plugged 1 Programming – manual into one BNG/BVNG 650-… The For more information, see bus video line rectifier accessory page 50 ZBVNG 650-…...
  • Page 51: Activating The Bus Line Rectifier

    7.1 Programming – manual Activating the bus line rectifier To activate the programming mode at the bus line rectifier, the program- ming mode button has to be briefly pressed down. LED 1 indicates whether the programming mode is switched on. After activating the programming mode, LED 1 changes over from normal mode to program- ming mode.
  • Page 52: Activating The Bus Door Loudspeaker

    7.1 Programming – manual Activating the bus door loudspeaker Depending on the type of door sta- tion, the programming mode has to be activated in a different way. 1 Siedle Vario 2 Siedle custom-fit door loud- 3 Siedle Classic speaker In the case of door loudspeaker CL V xx B-02 is set to the program- module BTLM 650-…...
  • Page 53: Activating The Indoor Devices

    Activating the indoor devices Depending on the type of bus indoor device, the programming mode has to be activated in a different way. 1 Siedle Basic 2 Bus telephone 3 Bus handsfree telephone Hold down the speech button for Lift the receiver at the bus telephone Hold down the light button for 4 seconds.
  • Page 54: Activating Jung Indoor Devices

    7.1 Programming – manual Activating Jung indoor devices 1 Activate the standard audio 2 Activate the audio indoor indoor station station Hold down the light button for Hold down the light button for 4 seconds. A protracted acknowl- 4 seconds. A protracted acknowl- edgement tone sounds as confirma- edgement tone sounds as confirma- tion and the muting button begins...
  • Page 55: Door Call To Siedle Basic

    Door call to Siedle Basic 1 Switch on the programming mode. 2 At the door station, hold down 3 Hold down the speech button for At the BNG/BVNG 650-…, press the the light/programming button for 4 seconds. A protracted acknowl- programming mode button briefly. 4 seconds.
  • Page 56: Door Call To Bus Telephone

    7.1 Programming – manual Door call to bus telephone At the bus telephone, a different ringtone optionally be selected. The volume of the door call can be changed at the bus telephone. 1 Switch on the programming mode. 2 At the door station, hold down 3 Lift the receiver at the bus tele- At the BNG/BVNG 650-…, press the the light/programming button for...
  • Page 57: Door Call To Bus Handsfree Telephone

    Door call to bus handsfree telephone At the bus handsfree telephone a volume of the door call can be different ringtone can optionally changed at the bus handsfree tele- be selected for the door call. The phone. 1 Switch on the programming mode. 2 At the door station, hold down 3 Hold down the light button for At the BNG/BVNG 650-…, press the...
  • Page 58: Door Call Via The Storey Call 10 Button

    7.1 Programming – manual Door call via the storey call button Programming is only possible when If there is no access available to an the storey call button (ERT) is con- apartment, programming can still be nected to the bus indoor device. carried out in this way.
  • Page 59: Parallel Door Call

    Parallel door call Where a door call has to be signalled Using the manual programming For more information, see at several bus telephones simulta- method, 2 bus indoor devices can be page 84 neously. programmed in parallel. Tel. 1 1 Switch on the programming mode. 2 At the door station, hold down 3 Lift the receiver at the bus tele- At the BNG/BVNG 650-…, press the...
  • Page 60: Internal Call

    7.1 Programming – manual Internal call You wish a bus telephone to be bus telephone can be reprogrammed able to call and communicate if required for internal call functions. with another bus telephone in the With the deluxe bus telephone up system.
  • Page 61 Tel. 1 Tel. 2 7 At the first bus telephone, hold 8 At the second bus telephone, hold 9 Replace the receiver at both bus down the internal call button you down the internal call button you telephones. Program additional bus wish to use to call the second bus wish to use to call the first bus tele- telephones using the same proce-...
  • Page 62: Dialling The Door Station

    7.1 Programming – manual Dialling the door station You wish to be able to call one or This function can be programmed more door stations from a bus tele- for any bus telephone to any button. phone using buttons, e.g. in order to The only exception is the door selectively speak to a visitor.
  • Page 63: Call Differentiation Of 2 Door Stations

    Call differentiation of 2 door stations At the bus telephone you wish to be Call differentiation can take place able to tell at which door the door from max. 2 doors. call has been made, e.g. whether a Door call 1 = Tone sequence 1 door call has come from the main Door call 2 = Tone sequence 2 entrance or a side entrance.
  • Page 64: Additional Contact On The 18 Bsm 650-... 64

    7.1 Programming – manual Additional contact on the BSM 650-… In addition to an already pro- Actuation of an additional bell or grammed bus telephone, you wish lamp on placement of a door call. a potential-free switching contact to be closed when a door call is placed. 1 Switch on the programming mode.
  • Page 65: Button Of A Bus Telephone On The Bsm 650

    Button of a bus telephone on the BSM 650-… Actuation of a contact in the Using the bus programming soft- BSM 650-…, e.g. in order to open a ware BPS 650-… the switching func- garage or switch on a staircase light. tion/time can now be changed. 1 Switch on the programming mode.
  • Page 66: Parallel Door Call To Bse 650

    7.1 Programming – manual Parallel door call to BSE 650-… The bus telephone must already be Potential-free switching contact Due to the structure design, the programmed to the call button. which is closed on placement of a BSE 650-… can be mounted in a 70 door call.
  • Page 67 Door call to BSE 650-… Potential-free switching contact which is closed on placement of a door call. Due to the structure design, the BSE 650-… can be mounted in a 70 junction box. 1 Switch on the programming mode. 2 At the door station, hold down 3 Switch the BSE 650-…...
  • Page 68: Button Of A Bus Telephone On The Bse 650

    7.1 Programming – manual Button of a bus telephone on the BSE 650-… Actuation of additional functions Using the bus programming soft- such as switching on the staircase ware BPS 650-… the switching func- light or garage door OPEN/SHUT. tion/time can now be changed. Switching time with manual pro- gramming 1 second.
  • Page 69: Bus Secondary Signal Unit Bns 750

    Bus secondary signal unit BNS 750-… Signal device to additionally indicate be used every time. For more information, see the door call and/or storey call in For activating an indoor device page 53 another room. (switching to the programming Where there are several doors, the mode).
  • Page 70: Call Via Drm 612

    7.1 Programming – manual Call via DRM 612-… Bus telephones are called from the The names in the display call module software PRS 602-… For connection door station via the display call DRM 612-… must be assigned of the PC to the DRM 612-… the module DRM 612-…...
  • Page 71: Call Via Com 611

    Call via COM 611-… Bus telephones are called by the door station via the COM 611-… code lock module. 1 Switch on the programming mode. 2 At the door station, hold down 3 Hold down the light button for At the BNG/BVNG 650-…, press the the light/programming button for 4 seconds.
  • Page 72: Door Call To Jung Indoor Station

    7.1 Programming – manual Door call to Jung indoor station At the Jung indoor station, a dif- The volume of the door call can be ferent ringtone can optionally be changed at the Jung indoor device. selected for the door call. 1 Switch on the programming mode.
  • Page 73: Parallel Door Call To Jung Indoor Station

    Parallel door call to Jung indoor station A door call has to be signalled at several Jung indoor stations simul- taneously. 1 Switch on the programming mode. 2 At the door station, hold down 3 Audio indoor station 1: At the BNG/BVNG 650-…, press the the light/programming button for Hold down the light button for programming mode button briefly.
  • Page 74: Internal Call Between Jung Indoor Stations

    7.1 Programming – manual Internal call between Jung indoor stations You wish a Jung indoor station to be able to call and communicate with another Jung indoor station in the system. 1 Switch on the programming mode. 2 Audio indoor station 1: 3 Audio indoor station 2: At the BNG/BVNG 650-…, press the Hold down the light button for...
  • Page 75 7 Switch off the programming mode at the BNG/BVNG 650-…...
  • Page 76: Basics

    7.2 Programming – Plug+Play Basics Plug+Play programming offers the Conditions for Plug+Play: Reset Plug+Play: opportunity for those without pro- • Install the system in accordance All already connected bus tele- gramming experience to commission with the wiring diagram. phones must be locked into position an In-Home bus system.
  • Page 77 Bus custom-fit door loudspeaker Siedle Classic The sequence of terminals on the The sequence of terminals on the bus call button matrix corresponds bus call button matrix corresponds to the sequence of bus telephones. to the sequence of bus telephones. The uppermost button is button 1, Terminal 7.1 = Bus telephone 1...
  • Page 78: Example Of A 4-Family Home

    7.2 Programming – Plug+Play Example of a 4-family home Apartment 1 Apartment 2 Apartment 3 Apartment 4 Restrictions Possible errors • Bus telephones which are already • If unsuitable devices log in during assigned to a door loudspeaker Plug+Play programming (old bus in the same line are not repro- telephone models such as BTS/ grammed.
  • Page 79: Procedure - Example

    Procedure – Example Apartment 1 Apartment 1 click Apartment 2 Apartment 2 Apartment 3 Apartment 3 Apartment 4 Apartment 4 1 Activate the Plug+Play-mode at 2 Set up the bus telephone in 3 Set up the bus telephone in the BNG/BVNG 650-…, hold down apartment 1 with the receiver in apartment 2 with the receiver in the programming mode button for...
  • Page 80: Programming – With Pc Bps 650-... And Pri 602

    7.3 Programming – with PC BPS 650-… and PRI 602-… USB Using bus programming software Mobile operation BPS 650-… the entire function of an In-Home system can be programmed using a Windows PC. For connection of the PC to the In-Home installa- tion, the programming interface PRI 602-… USB and the bus power supply accessory ZBVG 650-…...
  • Page 81: Switching And Control Functions

    8 Supplementary functions Switching and control functions Bus switching unit Bus switching module Bus input module In-Home: Audio In-Home: Audio In-Home: Audio Actuation 4 - 30 V DC, 10 mA max. Potential-free 24 V AC / DC existing contact 250 V AC / 6 A Supply 12 V AC BSM 650-…...
  • Page 82: Door Release Actuation

    8 Supplementary functions Door release actuation In deviation from the standard plans, are operated within a system, both the door release can be actuated in contacts are required to open the various ways. The bus line rectifier door station. In general, high-resist- BNG/BVNG 650-…...
  • Page 83 Application Systems with more than one door station with door release. The Tö contact (door release con- tact) in the bus line rectifier and the BTLM door release contact in the door loudspeaker are used. The contact in the BNG/BVNG 650-… switches the door release button every time it is pressed, the contact in the door loudspeaker only at the door from...
  • Page 84: Parallel Door Call

    8 Supplementary functions Parallel door call Manual programming Programming with PC and BPS In case of manual programming In general, 2 telephones can During PC programming, only 2 bus telephones can be be switched in parallel. Parallel 4 AIB 150-…, BTS/BTC/BFC 850-… programmed in parallel without operation can be extended when units can be programmed in parallel ZPS 850-…...
  • Page 85 A maximum of 8 ZPS/ZPSF 850-… units can be supplied by a video line rectifier NG 602-… The maximum current of the 30 V DC direct voltage from the VNG 602-… is 1100 mA. The specified ranges only apply to the external power supply to the devices, not to the range of the In-Home bus.
  • Page 86 8 Supplementary functions Parallel door call Parallel programming of several bus • Manual programming with 8 BTC/ • BTS 850-… and AIB 150-… can telephones to one call button. BFC 850-… units is possible if only be programmed as 1–4 bus • On principle, all combinations can from the 3rd bus telephone each telephones be programmed with BPS 650-…...
  • Page 87 Supply of Jung audio indoor apply to the external power supply stations of the devices, not to the ranges of A maximum of 15 Jung audio the In-Home bus. Ranges applicable indoor stations can be supplied by a for J-Y(ST)Y or YR installation cable VNG 602-…...
  • Page 88: Storey Call Parallel Switching

    8 Supplementary functions Storey call parallel switching Storey call parallel switching The storey call button (ERT) is used to call into the apartment from an apartment door. To call several bus telephones, the ERT terminal can max. 50 m be connected in parallel, e.g. office floor with 4 bus telephones with one storey call button at the storey entrance.
  • Page 89: Bps 650

    Supplementary contact, radio chime, pilfer safeguard Supplementary contact in the bus indoor device The bus indoor devices provide an additional contact at terminals In-Home-Bus: Audio S1/S1. Actuation of an additional signal- ling device such as a radio chime or optical display of the door call. If the contact is required in the sub-distributor, the door call can be programmed to a contact at a BSE/...
  • Page 90: Staircase Light/Outside Light

    8 Supplementary functions Staircase light/Outside light Light actuation The light button in the bus indoor devices or BTLM 650-… is used to actuate the light contact in the bus line rectifier BNG/BVNG 650-… . Following completion of the instal- lation, this function is active without 230 V AC any further programming.
  • Page 91: Servicing

    9 Servicing Restart, exchange, operating mode Restarting the system Exchanging bus telephones in an eration bus users. The performance A restart of the complete system is existing system features on the In-Home bus are known as a Power-ON-Reset. If an already programmed bus not fully available in switch setting Switch off the power supply to the telephone has to be exchanged,...
  • Page 92 9 Servicing Restart, exchange, operating mode Operating mode switch 1-Norm-2 BNG 650-… Switch setting 1 Switch setting “Reverse compatible“ “Norm“ BTS 750-0 AIB 150-… BTC 750-0 BTS 850-…/BFS 850-… BNS 750-0 BTC 850-…/BFC 850-… BTLM 650-0/-01 BTS 750-02 BTLE 050-0/-01 BTC 750-02/-03 BSM 650-0 BNS 750-02 BIM 650-0 BTLM 650-02/-03 DCA 650-0 BTLE 050-02/-03 BSM 650-02 BIM 650-02 BSE 650-0 BEM 650-0 DCA 650-02 CSA/SBA/STA 850-…...
  • Page 93: Led Displays Bng 650

    LED displays BNG 650-… The two displays LED 1 and LED 2 at the bus line rectifier indicate functions for operation and possible faults in the In-Home bus. The fol- lowing table indicates the possible displays. Display LED 1 “Operation“ LED flashes evenly 0,3s 0,3s 0,3s 0,3s...
  • Page 94: Measured Values

    9 Servicing Measured values Measured values at the In-Home bus: Audio, to be measured with a digital multimeter Idle status min. max. Voltage Ta/Tb at bus line rectifier BNG 650-… 26 V DC 29 V DC Voltage at most distant user 16 V DC Current consumption bus indoor devices 6 mA Current consumption bus door loudspeaker...
  • Page 95: 10 Glossary, Index

    10 Glossary, Index Technical additions or printing errors Address 9, 21 AIB 150-… do not constitute grounds for com- As-delivered status BEM 650-… 13, 81 pensation claims. Outside light BFC 850-… Exchange BIM 650-… The latest issues of the In-Home Bus Operating mode switch 50, 91 BNG 650-…...
  • Page 96 S. Siedle & Söhne © 2015/07.17 Telefon- und Telegrafenwerke OHG Printed in Germany Best.-Nr. 210007097-00 EN Postfach 1155 78113 Furtwangen Bregstraße 1 78120 Furtwangen Telefon +49 7723 63-0 Telefax +49 7723 63-300 www.siedle.de info@siedle.de...

Table of Contents