4 Components for DCIP 600-...

Input module, camera module

CMC 612-...
Camera module, colour. Integrated
2-step heating system, day/night
switchover, infrared lighting and
video signal transformer. Power
supply using line rectifier NG 600-...
or VNG 602-... With Siedle Multi via
PCM 640-.../NG 600-..., NG 608-...
or NG 640-... Heating power supply
12 V AC, 100 mA.
COM 611-01
Code lock module as an input unit
in conjunction with the Siedle Vario
bus.
A C button for deleting incorrect
inputs. LED as status display
(external potential-free contact).
Operating voltage 12 V AC /DC
Current consumption max. 100 mA
AEM 645-0
Alphabetical input module with
keypad A - I. Input unit for
alphanumerical selection of PC users.
For use in Siedle Multi systems only
in conjunction with the TLC 640-02,
COM 611-01
DIM 640-0 and SIVS 600-...
Operating voltage 12 V AC /DC
Current consumption max. 100 mA
DRM 611-0
Display call module as an input unit
with 4-line display for placing door
calls.
To scroll through the name index,
there are two arrow keys provided
for „up/down". An external DR
button can be connected.
• 4-line display x 18 characters each,
with LED backlighting
• 3 displacement-free piezo buttons
• Button actuation confirmed by
Ambient temperatue
-20°C to +70°C
Dimensions: 99 x 99 mm
acoustic tone
• Backlit symbols
Operating voltage 12V AC/DC
• Current consumption max. 200
mA
Ambient temperature
-20°C to +70°C
Dimensions: 99 x 99 mm