DCIP 600-... system-free with

COM 611-...

Functional characteristics
Up to 49 PC users (Software Clients)
of a network can be called from
the door station via the code lock.
Calling, speech and door release via
the Software Client DCIP SC 600-...
The Software Client must be
installed on every PC which receives
calls.
For calls via the code lock module,
for each user a freely selectable
call number (max. 22 digits) can
be entered. The call numbers can
agree, for instance, with an existing
telephone directory.
Standard call tones for the Software
Client 3-tone chime. A dedicated
*.wav file can be assigned for each
call tone.
It is not possible to listen in to an
existing call from other PC users in
the network.
The door is opened by the called
PC user using a "virtual door
release button", the light switching
function is actuated using a "virtual
light button". The door call can be
muted with an optical display on the
monitor.
Supplementary functions
• Up to 25 PC users can be called in
parallel with a call button from the
door station.
• Every PC user to which a door
call has been established occupies
currently 2 registrations in the IPVS.
Remarks
a) Door release 12 V AC, use at least
20 Ohm (e.g. TÖ 615-...)
b) The NG 600-0 can also take
over the power supply to existing
on-site call buttons. A voltage of
12 V AC max. 200 mA is available
for the lighting if a door release
with an impedance of at least
20 Ohm is used. With a higher
current consumption, an additional
transformer must be used.
• 12 V AC consumers in the wiring
diagram:
• Door release appr. 600 mA
Camera heating appr. 100 mA
• Door release contact load in the
SIVS 600-... max. 24 V AC, 1 A
• Light contact load in the door
loudspeaker max. 24 V AC, 2 A
c) Distance of the SIVS 600-... to the
door station max. 200 m with
J-Y(ST)Y 0.8 mm core material.
Distance between the two devices
SIVS 600-... and IPVS 600-... in
the distributor max. 1 m. During
installation, ensure that the door
release is laid in a separate cable.
Power supply to the SIVS 600 15 V
DC (terminal bv+/cv-), max. 300 mA.
d) ***Optionally the DCA 740-01
can be connected to the PBX
extension of a telephone system.
Active door calls can then be routed
via the telephone. The functional
features of the Software Client can
still be used.