4 Device overview only DCIP 600-...
System-free operation
12
SIVS 600-0
System interface video server for
connection of the TLM/LL 611-...
Conversion of signals from the door
loudspeaker to the IPVS 600-0.
Manages assignment, i.e. how
which PC is called. Connection of
modules COM 611-..., AEM 645-...,
TME 645-... or DRM 611-... possible.
Dimensions 144 x 130 x 55 mm
TLM/LL 611-01
Door loudspeaker module for
interfacing at a symmetrical or
asymmetrical line interface, with
integrated electret microphone
and loudspeaker. Integrated echo
compensation for full duplex
operation. Potential-free light
button capable of illumination, and
controllable volume.
Power supply 15-28 V DC
max. 100 mA
Line-In 800 mV eff
Impedance 2 kOhm
Line-Out 100 mV eff
Impedance 100 Ohm