Contents 1 In-Home bus: Video Siedle custom-fit Additional contact on the door loudspeaker BSM 650-… System description Siedle Classic Button of a bus telephone on 2 Siedle Systemtechnik the BSM 650-… Siedle Steel Jung indoor stations Deleting the assignment on the Siedle Vario with Intercom 3 Safety remarks BSM 650-…...
1 In-Home bus: Video 2 Siedle Systemtechnik 3 Safety remarks System description Jung indoor stations Danger Configuration “Single line“ “Siedle Systemtechnik” and the The In-Home bus: Video features relevant logo are used to describe the same basic structure as a Siedle devices, components or systems In-Home bus: Audio installation.
4 Configuration, conductor lengths Single line system Configuration of In-Home: Video Conductor material The basic Siedle In-Home bus instal- Telecommunication or light current lation type is the single line system. conductors can be used for instal- Within this one line, installation lation: takes place from one device to the J-Y(St)Y...
Page 7
branch are not laid in the same cable. Forward and return lines to a bus telephone with video must not be laid in the same cable. Otherwise, picture disturbance may result. If installation from one bus tele- phone to the next bus telephone is not possible, bus distributors must be used.
4 Configuration, conductor lengths Single line system with bus distributor Conductor length with bus If the maximum admissible atten- distributor uation of 45 dB is exceeded, the If the use of bus distributors is nec- bus video line rectifier accessory essary for installation, in addition to ZBVNG 650-…...
Single line system with bus distributor and ZBVNG 650-… Conductor length with bus dis- tributor and ZBVNG 650-… The ZBVNG 650-… accessory ampli- fies the video signal, so permitting greater attenuation in the camera branch and monitor branch. To do this, the inserted jumper card in the BVNG 650-…...
4 Configuration, conductor lengths Multiple line system Line 1 Line 2 Line 15 J-Y(St)Y Most distant BVNG-BVNG (SaV/SbV) connection max. 150 m/492 ft...
Page 11
Configuration of the multiple Conductor length between the line system lines A multiple line system comprises The admissible conductor lengths individual lines which are linked within a line are identical to those together by two cores. The lines in a single line system. In addition, are connected at the bus video line the admissible conductor length rectifier using terminals SaV and SbV.
4 Configuration, conductor lengths Example to determine the attenuation Example to determine the atten- Attenuation in the monitor uation with bus distributor branch to apartment 1 The system is installed using J-Y(St)Y Conductor length of the installation BVVU cable 0.8 mm diameter. This means cable.
Installation with YR Installation with J-Y(St)Y, increased range Installation with YR If it is necessary to use bus distrib- Systems can also be configured with utors within the installation, the using conductor material YR with a attenuation of the conductor mate- core diameter of 0.8 mm.
4 Configuration, conductor lengths Bus distributor for flush mounted junction boxes Camera branch: Camera branch Monitor branch No bus distributor required with a door station. Monitor branch: No bus distributor required when looping through from bus telephone to bus telephone. The integrated bus distributor in the bus tele- phones is used.
Attenuation values Video user Direction Video user Direction Direction Video user Line Line Line rectifier rectifier rectifier Video user Video user Audio user Attenuation Attenuation Attenuation BVVS 650-... BVVU 650-... BAA 650-... BAA 650-… in the BVVS 650-… in the BVVU 650-… in the camera branch camera branch camera branch...
4 Configuration, conductor lengths Bus distributor for top hat rail mounting BVVS 652-… in the camera branch: Distribution Distribution More than one video door station in the BVVS 1 BVVS 1 camera branch with “star shaped” con- ductor routing. BVVS 652-… in the monitor branch: Within the In-Home bus: Video more than one side circuit is required.
Attenuation values BVVS 1 Video user Direction Line Audio user Video user rectifier Video user Video user Direction Video user Direction Line BVVS 2 Line rectifier rectifier Video user Direction Line Video user Video user rectifier Video user Attenuation Attenuation 12 dB Attenuation 2 dB...
5 In-Home: Video users Door loudspeakers, call buttons BTLM 650-04 BTM 650-01 to -04 DRM 612-01 Bus door loudspeaker module for Bus call button modules for In-Home Display call module as an input In-Home bus. Loudspeaker and bus 1–4 call buttons, integrated LED device with 4-line display for placing microphone integrated, illuminated lighting.
Door stations Siedle Classic Siedle Steel Door station in the Classic design Door station in the Steel design line, with stainless steel front, line, with stainless steel front, door loudspeaker, call buttons and door loudspeaker, call buttons and Bus camera. LED-illuminated bell Bus camera.
5 In-Home: Video users Bus and external cameras BCMC 650-03 BCM 651-0 BCM 653-01 Bus camera 80 for Siedle Vario with Bus camera 80 for Siedle Vario with Bus camera 130 for Siedle Vario with automatic day/night switchover (True automatic day/night switchover (True automatic day/night switchover (True Day/Night) and integrated infrared Day/Night) and integrated infrared...
Page 21
BCM 658-01 CE 600-01 CE 950-01 Bus camera 180 for Siedle Vario with Colour CCD video camera external Colour CCD video camera external automatic day/night switchover. mounting with automatic day/night mounting with automatic day/night Horizontal/vertical pick-up angle: switchover (True Day/Night) and inte- switchover (True Day/Night) and inte- appr. 165°/135°...
5 In-Home: Video users Bus distributor, Bus video modulator BAVU 652-0 BVVU 652-0 BVVS 652-0 Asymmetrical bus audio/video dis- Asymmetrical bus video distributor Symmetrical bus video distributor for tributor for top hat rail mounting for for top hat rail mounting comprising top hat rail mounting comprising 2 connection of pure audio compo- 2 internally linked distributors for...
Page 23
BVM 650-0 The bus video modulator in switch panel housing connects an analogue camera with the In-Home bus. There are two operating modes to choose from, the analogue camera can be operated with or without a door station. A distance of up to 100 m between the camera and the BVM 650-…...
5 In-Home: Video users Power supply, line rectifiers BVNG 650-0 VNG 602-02 TR 603-0 Bus video line rectifier in a 9-grid Video line rectifier in a 10-grid Transformer in a 3-grid housing. housing. housing. Primary: 230 V AC, 50/60 Hz Primary: 230 V AC, 50/60 Hz, Primary: 230 V AC, 50/60 Hz Secondary: 12 V AC, 1.3 A door release contact 15 V AC,...
Switching, control BSM 650-02 BSE 650-01 BEM 650-01 Bus switching module in 3-grid Bus switching unit with bistable Bus input module for mounting in housing. 4 integrated relays, each relay, suitable for mounting in a 70 a 70 junction box with an input for with a potential-free working con- junction box.
5 In-Home: Video users Gateway, Software, License, PC interface, DoorCom SG 150-0 BSHT 650-0 SG 650-0 Smart Gateway: top hat rail device Smart Gateway Professional: top hat The virtual in-house telephone for private or professional use. rail device for private or professional assumes the function of a video Interface between In-Home bus and use.
Page 27
PRI 602-0 PRI 602-01 USB BPS 650-0 Programming interface for con- Programming interface for con- Bus programming software for nection of a Windows PC via serial nection of a Windows PC via USB programming In-Home bus systems. interface to the Vario bus. The Vario port to the ZBVG 650-…...
5 In-Home: Video users Bus indoor devices AIB 150-01 BTS 850-02 BTC 850-02 Audio indoor station Siedle Basic: Standard bus telephone. Connection Deluxe bus telephone. Connection Handsfree station for surface at bus cores Ta and Tb. at bus cores Ta and Tb. mounting.
Page 29
BFC 850-0 BTSV 850-03 BTCV 850-03 Deluxe handsfree bus telephone Standard bus telephone with colour Comfort bus telephone with colour intercom. Connection at bus cores monitor for Siedle in-home bus monitor for door and internal Ta and Tb. Functions: telephony. Functions: •...
Page 30
5 In-Home: Video users Bus indoor devices VIB 150-0 BFCV 850-02 Video indoor station Siedle Basic: Deluxe handsfree bus telephone Video handsfree station for surface intercom with colour monitor for mounting. Siedle In-Home bus Entry-level device with all essen- Functions: tial functions in the accustomed •...
Page 31
BVPS 850-0 BVPC 850-0 Standard bus video panel with Deluxe bus video panel with colour display 17.8 cm for the Siedle touchscreen 17.8 cm for the Siedle In-Home bus. In-Home bus. Functions: Functions: • Calling, speech, vision, door • Calling, speech, vision, door release, light, storey call/switching/ release, light, storey call/switching/ control functions, signal displays and...
5 In-Home: Video users Jung indoor stations SI 4 A .. SI AM … SI VM … Audio indoor station standard The audio module is the basic The video module has a TFT colour Audio indoor station design standard module of the modular structured monitor with a screen diagonal of Calling, speech, door release, light, flush mounted indoor station.
Table-top accessory ZTS 800-01 ZTC 800-0 ZTCV 850-0 Standard table-top accessory for Deluxe table-top accessory for the Table-top accessory for bus tele- bus telephones BTS/BFC 850-… for bus telephone BTC 850-… for con- phones with colour monitor BTCV/ conversion from a wall-mounted to version from a wall to a table top BFCV 850-…...
5 In-Home: Video users Accessory ZBVNG 650-0 ZBVG 650-0 BNS 750-02 Bus video line rectifier accessory as Bus supply unit accessory as a Bus secondary signal unit, for a plug-in card for installation in bus plug-in card for integration in bus signalling door and storey door video line rectifier BVNG 650-…...
Page 35
ZPSF 850-0 ZPS 850-0 ZARF 850-0 Parallel switching accessory for Handsfree interfacing relay accessory Parallel switching accessory for inte- integration into deluxe bus tele- for integration in the handsfree bus gration into deluxe handsfree bus phone BTC 850-… Circuit board telephone BFC 850-… Universal telephone BFC 850-…...
6 Installation General information Installation Consumers Voltage Current In each bus indoor device with Door release 12 V AC appr. 600 mA colour display, there is a terminating circuit board connected in the as-de- Camera heating 12 V AC 130 mA livered status in the centre of the Vario bus call button module 12 V AC max.
Bus call button module, bus video line rectifier Bus call button module Connection of the bus call button BTLM 650-04 BTLM 650-04 modules to the bus door loud- speaker via ribbon cable. The name plate lighting is supplied from the terminal block of the BTLM 650-04.
6 Installation Modular Jung indoor station Every module is mounted in a flush-mounting junction box in compliance with DIN 49073. We rec- ommend using a deep junction box SI VM ... for mounting. Mounting takes place using the provided support rings. Mounting can take place in combi- nation or individually –...
Page 39
Audio combinations Item no. Item designation SI AM … Audio module SI TM .. 5073 Standard call button module SI AM … Audio module SI TM .. 5093 Universal call button module SI AM … Audio module SI TM .. 5093 Universal call button module SI TM .. 5073 Standard call button module SI AM … Audio module SI TM .. 5093 Universal call button module SI TM .. 5093 Universal call button module Video combinations...
6.1 Installation video Siedle Vario with BVPS/BVPC 850-0...
Page 41
Siedle Vario with BVPS/ BVPC 850-0 Functional In-Home-Bus: Video Calling, speech and video functions between door station and the connected bus indoor devices with colour display. Audio and video privacy of existing calls from other bus indoor devices is assured. Door release button for the door release function, light button for the light switching function.
6.1 Installation video Siedle Vario with SG 150/650-0...
Page 43
Siedle Vario with SG 150/650-0 Supplementary functions Remarks • Internal speech communication a) The TR 603-… (12 V AC, 1.3 A) Functional between bus indoor devices is only can supply the door release, camera Calling, speech and video functions possible internally within the same heating and max. 30 bus call button between door station and the line.
Page 45
Siedle Vario Supplementary functions Remarks • Internal speech communication a) The TR 603-… (12 V AC, 1.3 A) Functional between bus indoor devices is only can supply the door release, camera Calling, speech and video functions possible internally within the same heating and max. 30 bus call button between door station and the line.
6.1 Installation video Siedle custom-fit door loudspeaker...
Page 49
Siedle custom-fit door loud- Supplementary functions Remarks speaker • Internal speech communication a) The NG 602-… (12 V AC, 1.6 A) between bus indoor devices is only can also provide a supply for illu- Functional possible internally within the same mination of existing call buttons. Calling, speech and video functions line.
Page 51
Siedle Classic Supplementary functions Remarks • Internal speech communication a) The TR 603-… (12 V AC, 1.3 A) Functional between bus indoor devices is only can supply the door release, camera Calling, speech and video functions possible internally within the same heating and max. 120 bus call between door station and the line.
Page 53
Siedle Steel Supplementary functions Remarks • Internal speech communication a) The TR 603-… (12 V AC, 1.3 A) Functional between bus indoor devices is only can supply the door release, camera Calling, speech and video functions possible internally within the same heating and max. 200 bus call between door station and the line.
Page 54
6.1 Installation video Siedle Vario with Intercom functions...
Siedle Vario with Intercom Basic functions with all bus Remarks functions indoor devices a) The TR 603-… (12 V AC, 1.3 A) • Internal speech communication can supply the door release, camera Functional between bus indoor devices is only heating and max. 30 bus call button Calling, speech and video functions possible internally within the same modules.
6.1 Installation video Siedle Vario 2 door stations...
Page 57
Siedle Vario 2 door stations Supplementary functions Remarks • Internal speech communication a) The TR 603-… (12 V AC, 1.3 A) Functional between bus indoor devices is only can supply the door release, camera Calling, speech and video functions possible internally within the same heating and max.
Page 59
Multiple line system Supplementary functions Remarks • Internal speech communication a) The TR 603-… (12 V AC, 1.3 A) Functional between bus indoor devices is only can supply the door release, camera Calling, speech and video functions possible internally within the same heating and max. 30 bus call button between door station and the line.
6.1 Installation video Call via display call module...
Page 61
Call via display call module Supplementary functions Remarks • Internal speech communication a) The TR 603-… (12 V AC, 1.3 A) Functional between bus indoor devices is only can supply the door release, camera Calling, speech and video functions possible internally within the same heating and max.
6.1 Installation video Additional external camera...
Page 63
Additional external camera Supplementary functions Remarks • Internal speech communication a) The NG 602-… (12 V AC, 1.6 A) Functional between bus indoor devices is only can supply the door release, camera Calling, speech and video functions possible internally within the same heating and max. 34 bus call button between door station and the line.
Page 65
Siedle Vario Supplementary functions Remarks • Internal speech communication a) The TR 603-… (12 V AC, 1.3 A) Functional between bus indoor devices is only can supply the door release, camera Calling, speech and video functions possible internally within the same heating and max. 30 bus call button between door station and the line.
6.2 Installation audio & video DoorCom Analog DCA 650-…...
Page 67
DoorCom Analog DCA 650-… Supplementary functions Remarks • Internal speech communication a) The TR 603-… (12 V AC, 1.3 A) Functional between bus indoor devices is only can supply the door release, camera Calling and speech between the possible internally within the same heating and max. 30 bus call button door station and the connected a/b line.
6.2 Installation audio & video Siedle Vario 3 door stations...
Page 69
Siedle Vario 3 door stations Supplementary functions Remarks • Internal speech communication a) The TR 603-… (12 V AC, 1.3 A) Functional between bus indoor devices is only can supply the door release, camera Calling, speech and video functions possible internally within the same heating and max.
Multiple line system Supplementary functions Remarks • Internal speech communication a) The TR 603-… (12 V AC, 1.3 A) Functional between bus indoor devices is only can supply the door release, camera Calling, speech and video functions possible internally within the same heating and max. 30 bus call button between door station and the line.
6.3 Siedle Systemtechnik installation Jung video indoor station...
Page 73
Jung video indoor station Supplementary functions Remarks • Internal speech communication a) The TR 603-… (12 V AC, 1.3 A) Functional between bus indoor devices is only can supply the door release, camera Calling, speech and video functions possible internally within the same heating and max. 30 bus call button between door station and the con- line.
Jung audio & video indoor Supplementary functions Remarks station • Internal speech communication a) The TR 603-… (12 V AC, 1.3 A) between bus indoor devices is only can supply the door release, camera Functional possible internally within the same heating and max. 30 bus call button Calling, speech and video functions line.
Page 76
6.3 Siedle Systemtechnik installation Jung standard audio indoor station & video indoor station...
Jung standard audio indoor sta- Supplementary functions Remarks tion & video indoor station • Internal speech communication a) The TR 603-… (12 V AC, 1.3 A) between bus indoor devices is only can supply the door release, camera Functional possible internally within the same heating and max.
Siedle and Jung indoor stations Supplementary functions Remarks combined • Internal speech communication a) The TR 603-… (12 V AC, 1.3 A) between bus indoor devices is only can supply the door release, camera Functional possible internally within the same heating and max. 30 bus call button Calling, speech and video functions line.
7 Programming Overview of functions Functions with Siedle In-Home and not available programming possibilities. Terms •/-/- Plug+Play programming used in the table are explained in -/•/- Manual programming detail on the next page. -/-/• PC programming Basic functions Door call •/•/•...
Page 81
Basic functions Door call •/•/• •/•/• •/•/• •/•/• •/•/• •/•/• -/•/• -/•/• -Storey call -Door release button -Light button -Call silencing and display (Functional following installation) Dialling last door -/-/• -/-/• -/-/• -/-/• -/-/• -/-/• -/•/• -/•/• (Functional following installation) Call tone configuration -/•/•...
Page 82
7 Programming Overview of functions Functions with Siedle In-Home and not available programming possibilities. Terms •/-/- Plug+Play programming used in the table are explained in -/•/- Manual programming detail on the next page. -/-/• PC programming Basic functions Door call •/•/•...
Page 84
7 Programming Overview of functions Dialling last door Internal call Call silencing and display The door station from which the last Bus indoor devices can place calls to The call can be switched off at the door call was placed can be dialled each other using the buttons.
Teach-in Term for manual programming of bus users. Door dialling One or more door stations can be selectively dialled and a speech con- nection established. Doormatic The door release contact in the bus video line rectifier and in the calling bus door loudspeaker switches for 3 seconds after the door bell button has been pressed.
7 Programming Remarks The In-Home bus can be pro- • In multiple line systems bus power Handsfree bus telephones grammed in three ways: supply accessory ZBVG 650-… Picking up and replacing the receiver must be additionally plugged are no longer necessary when 1 Programming –...
7.1 Programming – manual Activating the bus line rectifier To activate the programming mode over from normal mode to program- at the bus line rectifier, the program- ming mode. ming mode button has to be briefly pressed down. LED 1 indicates whether the programming mode is switched on.
7.1 Programming – manual Activating the bus door loudspeaker Depending on the type of door sta- tion, the programming mode has to be activated in a different way. 1 Siedle Vario 2 Siedle custom-fit door loud- 3 Siedle Classic speaker In the case of door loudspeaker CL V xx B-02 is set to the program- module BTLM 650-…...
Activating the indoor devices Depending on the type of bus indoor device, the programming mode has to be activated in a dif- ferent way. 1 Siedle Basic 2 Bus telephone 3 Bus handsfree telephone Hold down the speech button for Lift the receiver at the bus telephone Hold down the light button for 4 seconds.
7.1 Programming – manual Activating Jung indoor devices 1 Activate the standard audio 2 Activate the audio indoor 3 Activate the video indoor indoor station station station Hold down the light button for Hold down the light button for Hold down the light button for 4 seconds.
Door call to Siedle Basic 1 Switch on the programming mode. 2 At the door station, hold down 3 Hold down the speech button for At the BNG/BVNG 650-…, press the the light/programming button for 4 seconds. A protracted acknowl- programming mode button briefly. 4 seconds.
7.1 Programming – manual Door call to bus telephone At the bus telephone, a different ringtone optionally be selected. The volume of the door call can be changed at the bus telephone. 1 Switch on the programming mode. 2 At the door station, hold down 3 Lift the receiver at the bus tele- At the BNG/BVNG 650-…, press the the light/programming button for...
Door call to bus handsfree telephone At the bus handsfree telephone a The volume of the door call can different ringtone can optionally be be changed at the bus handsfree selected for the door call. telephone. 1 Switch on the programming mode. 2 At the door station, hold down 3 Hold down the light button for At the BNG/BVNG 650-…, press the...
7.1 Programming – manual Door call to Smart Gateway/Smart Gateway Professional Only one bus address can be To do so, the PRI 602-… USB assigned in the SG 150/650 with programming interface and the manual programming. If more bus BPS 650-… bus programming soft- addresses are required, PC program- ware is required.
Door call to standard bus video panel At the bus video panel, a different The volume of the door call can be The basic configuration must be car- ringtone can optionally be selected changed at the bus video panel. ried out on every device without fail. for the door call.
7.1 Programming – manual Door call to deluxe bus video panel At the bus video panel, a different The volume of the door call can be The basic configuration must be car- ringtone can optionally be selected changed at the bus video panel. ried out on every device without fail.
Door call via the storey call button Programming is only possible when If there is no access available to an the storey call button (ERT) is con- apartment, programming can still be nected to the bus indoor device. carried out in this way. 1 Switch on the programming mode.
7.1 Programming – manual Parallel door call Where a door call has to be signalled monitor must have an additional Programming must start at the bus at several bus telephones simulta- power supply. telephone to which no supplemen- neously. For more information, see tary power supply is connected.
Internal call You wish a bus telephone to be An internal call for the BVPC 850-… able to call and communicate is programmed at the PC using with another bus telephone in the the bus programming software system. BPS 650-… Tel. 1 Tel.
Page 100
7.1 Programming – manual Internal call Tel. 1 Tel. 2 7 At the first bus telephone, hold 8 At the second bus telephone, hold 9 Replace the receiver at both bus down the internal call button you down the internal call button you telephones.
Dialling the door station You wish to be able to call one or This function can be programmed more door stations from a bus tele- for any bus telephone to any button. phone using buttons, e.g. in order to The only exception is the door selectively speak to a visitor.
7.1 Programming – manual Selection external camera The BVM 650-… with switch External camera dialling can be The only exception is the door position 2 is used for connecting programmed as a function on a bus release button. an external camera without door telephone button.
Call differentiation of 2 door stations At the bus telephone you wish to be Call differentiation can take place able to tell at which door the door from max. 2 doors. call has been made, e.g. whether a Door call 1 = Tone sequence 1 door call has come from the main Door call 2 = Tone sequence 2 entrance or a side entrance.
7.1 Programming – manual Additional contact on the BSM 650-… In addition to an already pro- Actuation of an additional bell or grammed bus telephone, you wish lamp on placement of a door call. a potential-free switching contact to be closed when a door call is placed. 1 Switch on the programming mode.
Button of a bus telephone on the BSM 650-… Actuation of a contact in the In the BVPC 850-…, programming is Using the bus programming soft- BSM 650-…, e.g. in order to open a performed at the PC using bus pro- ware BPS 650-… the switching func- garage or switch on a staircase light.
7.1 Programming – manual Deleting the assignment on the BSM 650-… The assignments on the bus switching module can be deleted in delete mode. 1 Switch on the programming mode. 2 Switch the BSM 650-… to the pro- 3 Activate delete mode, to do so At the BNG/BVNG 650-…, press the gramming mode.
7.1 Programming – manual Parallel door call to BSE 650-… The bus telephone must already be Potential-free switching contact Due to the structure design, the programmed to the call button. which is closed on placement of a BSE 650-… can be mounted in a 70 door call.
Door call to BSE 650-… Potential-free switching contact which is closed on placement of a door call. Due to the structure design, the BSE 650-… can be mounted in a 70 junction box. 1 Switch on the programming mode. 2 At the door station, hold down 3 Switch the BSE 650-…...
7.1 Programming – manual Button of a bus telephone on the BSE 650-… Actuation of additional functions In the BVPC 850-…, programming is such as switching on the staircase performed at the PC using bus pro- light or garage door OPEN/SHUT. gramming software BPS 650-… Switching time with manual pro- gramming 1 second.
Bus secondary signal unit BNS 750-… Signal device to additionally indicate be used every time. For more information, see the door call and/or storey call in For activating an indoor device page 89 another room. (switching to the programming Where there are several doors, the mode).
7.1 Programming – manual Call via DRM 612-… Bus telephones are called from the The names in the display call module software PRS 602-… For connection door station via the display call DRM 612-… must be assigned of the PC to the DRM 612-… the module DRM 612-…...
Call via COM 611-… Bus telephones are called by the door station via the COM 611-… code lock module. 1 Switch on the programming mode. 2 At the door station, hold down 3 Hold down the light button for At the BNG/BVNG 650-…, press the the light/programming button for 4 seconds.
7.1 Programming – manual Door call to Jung indoor station At the Jung indoor station, a different ringtone can optionally be selected for the door call. The volume of the door call can be changed at the Jung indoor device. 1 Switch on the programming mode.
Page 115
Parallel door call to Jung indoor station A door call has to be signalled at several Jung indoor stations simul- taneously. 1 Switch on the programming mode. 2 At the door station, hold down 3 Video indoor station 1: At the BNG/BVNG 650-…, press the the light/programming button for Hold down the light button for programming mode button briefly.
7.1 Programming – manual Internal call between Jung indoor stations You wish a Jung indoor station to be able to call and communicate with another Jung indoor station in the system. 1 Switch on the programming mode. 2 Video indoor station 1: 3 Video indoor station 2: At the BNG/BVNG 650-…, press the Hold down the light button for...
Page 117
7 Switch off the programming mode at the BNG/BVNG 650-…...
7.2 Programming – Plug+Play Basics Plug+Play programming offers the Conditions for Plug+Play: Reset Plug+Play: opportunity for those without pro- • Install the system in accordance All already connected bus tele- gramming experience to commission with the wiring diagram. phones must be locked into position an In-Home bus system.
Page 119
Bus custom-fit door loudspeaker Siedle Classic The sequence of terminals on the The sequence of terminals on the bus call button matrix corresponds bus call button matrix corresponds to the sequence of bus telephones. to the sequence of bus telephones. The uppermost button is button 1, Terminal 7.1 = Bus telephone 1 remaining buttons follow in consec-...
7.2 Programming – Plug+Play Example of a 4-family home Apartment 1 BCM 653-0 Apartment 2 BTLM 650-04 Apartment 3 BTM 650-04 Apartment 4 Restrictions Possible errors • Bus telephones which are already • If unsuitable devices log in during assigned to a door loudspeaker Plug+Play programming (old bus in the same line are not repro- telephone models such as BTS/...
Procedure – Example Apartment 1 Apartment 1 Apartment 2 Apartment 2 Apartment 3 Apartment 3 Apartment 4 Apartment 4 1 Activate the Plug+Play-mode at 2 Set up the bus telephone in 3 Set up the bus telephone in the BNG/BVNG 650-…, hold down apartment 1 with the receiver in apartment 2 with the receiver in the programming mode button for...
7.3 Programming – with PC BPS 650-… and PRI 602-… USB Using bus programming software Mobile operation BPS 650-… the entire function of an In-Home system can be programmed using a Windows PC. For connection of the PC to the In-Home installa- tion, the programming interface PRI 602-… USB and the bus power supply accessory ZBVG 650-…...
8 Supplementary functions Switching and control functions Bus switching unit Bus switching module Bus input module In-Home: Audio In-Home: Audio In-Home: Audio Actuation 4 - 30 V DC, 10 mA max. Potential-free 24 V AC / DC existing contact 250 V AC / 6 A Supply 12 V AC BSM 650-…...
8 Supplementary functions Switching and control functions...
Page 125
Switching and control functions Switching and control functions Remarks Via bus audio decoupler BAA 650-… a) The TR 603-… (12 V AC, 1.3 A) Functional the devices for switching and con- can supply the door release, camera Calling, speech and video functions trol functions are connected to the heating and max.
8 Supplementary functions Door release actuation In deviation from the standard plans, are operated within a system, both the door release can be actuated in contacts are required to open the various ways. The bus line rectifier door station. In general, high-resist- BNG/BVNG 650-…...
Page 127
Application Systems with more than one door station with door release. The Tö contact (door release con- tact) in the bus line rectifier and the door release contact in the door loudspeaker are used. The contact BTLM in the BNG/BVNG 650-… switches the door release button every time it is pressed, the contact in the door loudspeaker only at the door from...
8 Supplementary functions Parallel door call, supplementary power supply, video memory Parallel door call current consumption of the bus Video memory Only possible within a line. telephones as well as the admissible When using the video memory in At the In-Home bus: Video can ring conductor length.
Page 129
A maximum of 3 VIB 150-…/BTSV/ BTCV/BFCV 850-… units can be supplied by a NG 602-… line rec- tifier. The maximum current of the 30 V DC direct voltage from the VNG 602-… is 1100 mA. The speci- fied ranges only apply to the external power supply to the devices, not to the ranges of the In-Home bus.
Page 130
8 Supplementary functions Parallel door call, supplementary power supply, video memory Power supply to 8 bus tele- button. Manual programming must phones start with the first bus telephone In the example, 8 bus telephones without power supply. have to be programmed to 1 call NG 602-…...
Page 131
Supply of 8 Jung video indoor specified ranges only apply to stations the external power supply to the A maximum of 6 SI VI … units can devices, not to the ranges of the be supplied by a VNG 602-… line In-Home bus. Ranges applicable for rectifier.
8 Supplementary functions Storey call parallel switching Storey call parallel switching The storey call button (ERT) is used to call into the apartment from an apartment door. For calls to several bus telephones, it is possible to con- nect the ERT terminal in parallel, e.g. office storey with 4 bus telephones and one storey call button at the storey entrance.
Supplementary contact, radio chime, pilfer safeguard Supplementary contact in the bus indoor device The bus indoor devices provide an additional contact at terminals S1/ Actuation of an additional signal- ling device such as a radio chime or optical display of the door call. If the contact is required in the sub-distributor, the door call can be programmed to a contact at a BSE/...
8 Supplementary functions Staircase light/Outside light Light actuation The light button in the bus indoor devices or BTLM 650-… is used to actuate the light contact in the bus line rectifier BNG/BVNG 650-… . Following completion of the instal- lation, this function is active without any further programming.
9 Servicing Restart, exchange, operating mode Restarting the system • The system can now be pro- • When the LED 1 indicates the A restart of the complete system is grammed again. normal operating mode again, the known as a Power-ON-Reset. previous system status has been Switch off the power supply to the Exchanging bus telephones in an...
9 Servicing Operating mode switch BVNG 650-… Exchanging the BVNG 650-… for Operating mode switch the BVNG 650-… 1-Norm-2 BVNG 650-… When exchanging the BVNG 650-… Switch setting 1 Switch setting in an existing system for the “Reverse compatible“ “Norm“ BVSG 650-…, the setting of the operating mode switch must be BTS 750-02 with BVE 650-0 AIB 150-…...
LED displays BVNG 650-… The two displays LED 1 and LED 2 at the bus line rectifier indicate functions for operation and possible faults in the In-Home bus. The fol- lowing table indicates the possible displays. Display LED 1 “Operation“ LED flashes evenly 0,3s 0,3s 0,3s 0,3s...
9 Servicing Measured values Measured values at the In-Home bus: Video, to be measured with using a digital multimeter Idle status min. max. Voltage TaM/TbM (TaK/TbK) at bus line rectifier BVNG 650-… 27 V DC 31 V DC Voltage at most distant user 19 V DC Current consumption bus indoor device with colour display 5 mA...
Need help?
Do you have a question about the AIB 150 Series and is the answer not in the manual?
Questions and answers