Summary of Contents for SSS Siedle DoorCom IP DCIP 600-0

  • Page 1 Manual DoorCom IP DCIP 600-0...
  • Page 2: Table Of Contents

    Contents 1 System description 2 Safety remarks System requirements 3 Structure DCIP 600-0 Group calculation Max. number of PC users Terms 4 Components Calling Input module, camera module Power supply, programming, IP video server Software System-free operation 5 Installation Wiring diagrams DCIP 600-0 Terminals DCIP 600-0 LED display SIVS 600-...
  • Page 3: System Description

    2 Safety remarks 1 System description System requirements DoorCom IP 600-0 DoorCom IP 600-0 Danger Find out about the necessary safety Siedle DoorCom IP links the Siedle measures and system requirements world of building communication before starting installation and to the IP world. Door calls are commissioning of the DoorCom IP.
  • Page 4: Dcip 600-0

    3 Structure DCIP 600-0 System-free PRI 602-... USB NG 600-0 DCIP 600-... audio and video to the IP network. • Text display of which door is System-free link One DCIP 600-... each is required calling. • Door release actuation by means The DoorCom IP 600-...
  • Page 5 3 Structure DCIP 600-0 System-free with link to telephone system DCA 740-01 NG 600-0 PRI 602-... USB Mounting and installation a telephone with DTMF capability. • Control commands such as door The devices are intended for switch For this purpose, the DCA 740-01 release and light possible from the panel mounting.
  • Page 6: Terms

    3 Group calculation Max. number of PC users 3 Terms and the individual PC users each Client For calculation of the maximum number of possible PC users (single occupy 5 registrations. In total, this PC user connected to a network. and parallel calls), the following rules adds up to 20*2+5+5=50, which is are applied:...
  • Page 7 is independent of the transmission on which the server runs is known medium. This means that computers as the host. can be grouped within a network into logical units known as subnets Subnet mask by means of an IP address and The subnet mask, also known subnet mask.
  • Page 8 4 Components for DCIP 600-... Call buttons BTM 650-01 - BTM 650-04 Bus call button modules for In-Home bus. 1-4 call buttons, integrated LED lighting. Connection via ribbon cable to the TME 645-... Power supply to the LED lighting via terminals b and c with 12 V AC/DC, current consumption 25 mA per bus call button module BTM 650-...
  • Page 9: Input Module, Camera Module

    4 Components for DCIP 600-... Input module, camera module CMC 612-... Camera module, colour. Integrated 2-step heating system, day/night switchover, infrared lighting and video signal transformer. Power supply using line rectifier NG 600-... or VNG 602-... With Siedle Multi via PCM 640-.../NG 600-..., NG 608-...
  • Page 10: Power Supply, Programming, Ip Video Server

    4 Components for DCIP 600-... Power supply, programming, video server NG 600-0 Line rectifier in 10-grid switch panel housing for universal power supply. Suitable for surface mounting with ZAP 10-0. Primary 230 V AC, 50 Hz, +6%-10% Secondary b/c: 14 V AC, 1 A; +/-: 24-28 V DC, 0.7 A Ambient temperature 0°C to +40°C, protection rating IP 20...
  • Page 11: Software

    4 Device overview for DCIP 600-... Software DCIP SC 600-0 Client on a PC, a licence is required DoorCom IP Software Client PC for the DCIP SC 600-0. program, which depicts a virtual house telephone with video on a PC monitor.
  • Page 12 4 Device overview only DCIP 600-... System-free operation SIVS 600-0 System interface video server for connection of the TLM/LL 611-... Conversion of signals from the door loudspeaker to the IPVS 600-0. Manages assignment, i.e. how which PC is called. Connection of modules COM 611-..., AEM 645-..., TME 645-...
  • Page 14 5 Terminals DCIP 600-... Terminals and LEDs IPVS 600-0 a No function b Connecting socket to the SIVS 600-... c RJ45 socket ETH network connection d Reset button to recreate the as-delivered status (after a reset, the Siedle modes must be reinstalled, see page 38.) e LED operating status lights up in green on readiness for operation...
  • Page 15 5 LED display SIVS 600-.../IPVS 600-... LED signalling SIVS 600-... Switching on LED green LED red Function After reset, power on: Device boots to operating status. The boot area is checked. Software runs in the flash Fast flashing After a software update, the boot area is recreated. This can take up to around 3 minutes.
  • Page 16: Block Diagrams

    5 Terminals SIVS 600-0, TLM/LL 611-01 Block diagram SIVS 600-0 Reference for inputs E1–E4 Input 4 Input 3 Input 2 Input 1 Supply voltage for Vario bus, 15 V DC, max. 300 mA Da/Db Vario bus Supply voltage 24 V DC Tö...
  • Page 17 5 Terminals CMC 612-0 Block diagram CMC 612-0 +M/-M Supply voltage Video 20 - 30 V DC Vc/- Actuation from door loudspeaker for camera on. With DoorCom IP the contact is permanently active. Potential - is switched via the UPS terminal. Actuation of camera distributor -M is switched...
  • Page 18: Dcip 600

    5 Installation DCIP 600-... system-free up to 4 users black Device requirement Remarks...
  • Page 19 DCIP 600-... system-free up to Remarks 4 users a) Door release 12 V AC, use at least 20 Ohm (e.g. TÖ 615-...) Functional characteristics b) The NG 600-0 can also take Up to 4 PC users (Software Clients) over the power supply to existing of a network can be called from the on-site call buttons.
  • Page 20: Dcip 600

    5 Installation DCIP 600-... system-free up to 4 users with DCA 740-...
  • Page 21 DCIP 600-... system-free up to Remarks 4 users with DCA 740-01 a) Door release 12 V AC, use at least 20 Ohm (e.g. TÖ 615-...) Functional characteristics b) The NG 600-0 can also take Up to 4 PC users (Software Clients) over the power supply to existing of a network can be called from the on-site call buttons.
  • Page 22 5 Installation DCIP 600-... system-free up to 49 users...
  • Page 23 DCIP 600-... system-free up to Supplementary functions loudspeaker max. 24 V AC, 2 A 49 users with TME 645-... • Connection of the COM 611-... is c) Distance of the SIVS 600-... to the possible in order to call PC users by door station max.
  • Page 24: Dcip 600

    5 Installation DCIP 600-... system-free with COM 611-...
  • Page 25: Com 611

    DCIP 600-... system-free with Remarks COM 611-... a) Door release 12 V AC, use at least 20 Ohm (e.g. TÖ 615-...) Functional characteristics b) The NG 600-0 can also take Up to 49 PC users (Software Clients) over the power supply to existing of a network can be called from on-site call buttons.
  • Page 26 5 Installation DCIP 600-... system-free with COM 611-... and AEM 645-...
  • Page 27 DCIP 600-... system-free with Remarks COM 611-... and AEM 645-... a) Door release 12 V AC, use at least 20 Ohm (e.g. TÖ 615-...) Functional characteristics b) The NG 600-0 can also take Up to 49 PC users (Software Clients) over the power supply to existing of a network can be called from the on-site call buttons.
  • Page 28: Dcip 600

    5 Installation DCIP 600-... system-free with DRM 611-...
  • Page 29 DCIP 600-... system-free with Remarks DRM 611-... a) Door release 12 V AC, use at least 20 Ohm (e.g. TÖ 615-...) Functional characteristics b) The NG 600-0 can also take Up to 49 PC users (Software Clients) over the power supply to existing of a network can be called from the on-site call buttons.
  • Page 30: Commissioning

    6 Commissioning DCIP 600-... system-free Commissioning of the DCIP 600-... is Connection of the PC to IPVS 600-... broken down into three steps: 1 Configuration of IPVS 600-... 2 Configuration of SIVS 600-... 3 Installation of the software DCIP SC 600-... on the PCs Step 1 on this page Configuration of IPVS 600-...
  • Page 31: Multicasting

    6 Configuration Multicasting Multicasting The following settings must be If audio signals have to be Alongside the 1:1 connection performed separately in each transmitted in multicasting mode, between one IPVS 600-... and one IPVS 600-..these must be assigned to their software client (Unicast) each, the own port as this is a separate data IPVS 600-...
  • Page 32: Configuration Software Dcip Co

    6 Configuration software DCIP CO 600-... Configuration of SIVS 600-... The configuration software DCIP CO 600-... is required for configuration of the SIVS 600-... Configuration takes place via a Windows PC. USB connection to the SIVS 600-... takes place via the PRI 602-... USB. With the configuration software, the call buttons are assigned to addresses.
  • Page 33: Software Client Dcip Sc

    the IPVS 600-.. for which the configuration is applicable. This input is required to ensure that the Software Clients are able to locate the DCIP in the network. • In the Inputs menu, all the IWA addresses are assigned. An IWA address for each call button/user.
  • Page 34 6 Client-Software DCIP SC 600-... Installation of the Software Clients The Software Client DCIP SC 600-... must be installed on every PC you wish to receive door calls. The Software Client communicates with the calling station, the DCIP 600-... After installation, the file (*.dcip) generated using the configuration software must be imported.The...
  • Page 35 Possible error sources Other settings in the Software • No speech connection from the Client: PC to the door. The microphone amplifier may not be activated. Free buttons • Installation must take place as Selection of functions for buttons administrator, so that all registered 1–3.
  • Page 36: Setting The Speech Volume

    7 Setting the speech volume Level adjustment DCIP 600-... Level adjustment IPVS 600-... Level adjustment TLM/LL 611-... Level adjustment DCA 740-... Setting the volume of the PC user in Setting the volume of the PC Set the volume of the speech the direction of the door station.
  • Page 38: Doorcom Dca 740-01

    9 DoorCom IP 8 DoorCom Factory setting IPVS 600-... DCA 740-01 The DoorCom Analog DCA 740-... telecommunication system or the With the reset button at the is used as an interface between a/b public network connection from IPVS 600-..., it can be reset to the DoorCom IP and an analog the exchange.
  • Page 39: Doorcom Ip Faq And Trouble Shooting

    10 DoorCom IP FAQ and trouble shooting Is brokering possible at the PC? failure (storm). Why does the DCIP SC 600-0.exe software have to be enabled in the When first accessing the PC client, firewall? Are telephone calls stored? the picture only appears after In order to permit a network around 30 seconds.
  • Page 40 10 Service Measured values Measurement values for DoorCom IP, to be measured using a digital multimeter Idle status min. max. Voltage +/- at line rectifier NG 600-... 24 V DC 28.5 V DC Voltage c/b at line rectifier NG 600-... 12 V AC Voltage b+/c- at SIVS 600-...
  • Page 41 Index 11 Glossary Connection AEM 645-... The current issue of the “ DoorCom IP “ system manual is As-delivered status BTM 650-... available from the download area Block diagram CMC 612-... under www.siedle.de. Client 6, 34 COM 611-... Commissioning DCA 740-... 10, 36 Technical additions and printing Config...
  • Page 42 S. Siedle & Söhne © 2007/02.09 Printed in Germany Postfach 1155 Order no. 0-1101/037154 EN D-78113 Furtwangen Bregstraße 1 D-78120 Furtwangen Tel. +49 7723 63-0 Fax+49 7723 63-300 www.siedle.de info@siedle.de...