DCIP 600-... system-free with
DRM 611-...
Functional characteristics
Up to 49 PC users (Software Clients)
of a network can be called from the
door station. Calling, speech and
door release via the Software Client
DCIP SC 600-... The Software Client
must be installed on every PC which
receives door calls.
For calls via the display call module,
a name can be assigned to each PC
user, e.g. Anton Anyone.
To scroll through the name index,
there are two arrow keys provided
for „up/down". When the required
name is highlighted in the list,
pressing the button with the bell
symbol will initiate a call to this user.
The DRM 611-... can also be used in
combination with the COM 611-...
in order to display the input via the
DRM 611-...
Standard call tones for the Software
Client 3-tone chime. A dedicated
*.wav file can be assigned for each
call tone.
It is not possible to listen in to an
existing call from other PC users in
the network.
The door is opened by the called
PC user using a "virtual door
release button", the light switching
function is actuated using a "virtual
light button". The door call can be
muted with an optical display on the
monitor.
Supplementary functions
• Connection of the COM 611-... is
possible in order to call PC users by
means of code selection.
• Up to 25 PC users can be called in
parallel with a call button from the
door station.
• Every PC user to which a door
call has been established occupies
currently 2 registrations in the IPVS.
Remarks
a) Door release 12 V AC, use at least
20 Ohm (e.g. TÖ 615-...)
b) The NG 600-0 can also take
over the power supply to existing
on-site call buttons. A voltage of
12 V AC max. 200 mA is available
for the lighting if a door release
with an impedance of at least
20 Ohm is used. With a higher
current consumption, an additional
transformer must be used.
• 12 V AC consumers in the wiring
diagram:
• Door release appr. 600 mA
Camera heating appr. 100 mA
• Door release contact load in the
SIVS 600-... max. 24 V AC, 1 A
• Light contact load in the door
loudspeaker max. 24 V AC, 2 A
c) Distance of the SIVS 600-... to the
door station max. 200 m with
J-Y(ST)Y 0.8 mm core material.
Distance between the two devices
SIVS 600-... and IPVS 600-... in
the distributor max. 1 m. During
installation, ensure that the door
release is laid in a separate cable.
Power supply to the SIVS 600 15 V
DC (terminal bv+/cv-), max. 300 mA.
When connecting additional devices
to the Vario bus (terminals Da/Db),
the Vario bus requires an additional
power supply.
d) ***Optionally the DCA 740-01
can be connected to the PBX
extension of a telephone system.
Active door calls can then be routed
via the telephone.
The functional features of the
Software Client can still be used.
29
Need help?
Do you have a question about the DoorCom IP DCIP 600-0 and is the answer not in the manual?