Installation instructions, only for experts

7.3. Terminal configuration humidity module (optional: WC4-H-PCB)

1. Voltage supply
The neutral wire "N" and the earth wire terminals"PE" are collective connections.
The right supply is internally connected to the base module (see page „Internal
main connection humidity board (optional: WC4-H-PCB)") angeklemmt.
The evaporator is conducted via the PG screw joint and connected to terminals
L(evaporator), N and PE.
The water deficiency connection can be connected to "res. 5" of the optional
humidity extension board WC4-H-PCB. The ventilator cable is inserted via the
cable screw joint and connected to terminals L(ventilator), N and PE. The outflow
has a 4A slow fuse.
Bench sensors and humidity sensors must be connected to the terminals provided
for on the humidity expansion board WC4-H-PCB.
Bench sensors and humidity sensors must be connected to the terminals provided
for on the humidity expansion board WC4-H-PCB.
Evaporator (230 V)
Ventilator (230 V)
Bench sensor
Humidity sensor
Dummy Sensor
p. 38/42