Technical Data; Power Unit Wc4-B-L - Harvia sentiotec wave.com4 Instructions For Installation And Use Manual

Sauna control unit
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 44
Installation instructions, only for experts

8. Technical data

8.1. Power unit WC4-B-L

Mains connection
Connection operating
unit
Control voltage
Mains cable
Light connection
Heating connection
Thermal fuse
Temperature sensor
Positioning accuracy
Power consumption
Ambient conditions
Casing
Fastening
Dimensions: L x W x H
Weight
For 3 x 400 V ~ 50 Hz with L1-L2-L3-N-PE; 1 x 230 V ~ 50
Hz with L-N-PE; casing only for standard domestic connec-
tion with fuse and residual current device and main switch.
RJ10; 4-pole with 5 V= supply and communication; length:
3 m
Low voltage 5 V=
Typical 5 x 2.5 mm² for heater
Typical 3 x 1.5 mm² for light and electronics
With integrated phase control dimmer, for 2 (3)-pole con-
nection of the 230 V filament lamp(s); max. 100 W
3 x 400 V~ 5-pole according to heater power rating up to
max. 3 kW or 14 A per phase
Integrated into the temperature sensor as overtemperature
protection; triggering temperature 139 °C
2-pole; semiconductor sensor -9 °C to 140 °C
+/- 1 °C; +/- 1 Min.
Operating mode FIN:
Operating mode HUM:
For light: max. 100 W
0 °C to max. 50 °C, max. 95 % rel. humidity, not condensing!
IP54
Via 4 mounting holes for M3 for screwing on
300 x 210 x 100 mm
~1114 g unpacked
max. 3 x 3 kW (heater)
max. 2 x 3 kW (heater)
max. 1 x 3 kW (evaporator)
p. 39/42
EN