9.3. AVB Input Streams

The AVB streams received by the M-1610 Pro are referred to as "input streams". For these streams, the
device acts as an AVB Listener.
To establish a connection between a talker and a listener, an AVDECC Controller is required. The M-1610
Pro does not include an AVDECC Controller.
AVB input streams are monitored as follows:
Description
Disabled
Streaming/Receiving
No Data
SR Mismatch
Waiting
Talker Fail
No Bandwidth
Domain Boundary
Internal Error

9.3.1. Change AVB Input Stream Size

Each of the eight AVB streams can have a size of 1-8, 12 or 16 channels in AM824 and AAF stream
formats, or 0 channels in CRF Media Clock stream format.
To change the amount of channels and format of incoming AVB streams on the device:
1. Open the AVB tab in the INPUT section.
2. Move the cursor to highlight the corresponding AVB stream size and press the encoder.
3. Rotate the encoder to configure a new stream size and format, then confirm by pressing the encoder
again.
RME M-1610 Pro User's Guide
Indicator
grey
green
red
red
yellow ...
red
red
red
red
Possible solution
Create connection with AVDECC
controller
Verify proper talker configuration
Verify that the sample rates of talker and
listener are identical
Waiting for talker to be ready
Verify proper talker configuration
Use faster network speed (1 GBit/s
instead of 100 MBit/s)
Reconnect all devices and reboot switch,
ensure only AVB switches are used
Reboot device