Furuno FSV-75 Operator's Manual page 195

Half-circle color scanning sonar
Hide thumbs Also See for FSV-75:
Table of Contents

Advertisement

Message
Processor unit
<< SHIP SPD
ALARM!! >>
Alarm and warning priorities
When multiple warnings occur at the same time, the warning with the highest priority
is displayed. The order of priority is as follows:
Priority
1
<<TD IS A HALT CONDITION!!>>
2
<<TRANSDUCER NOT
RETRACTED!! >>*
3
<<OVERVOLTAGE!! >>
4
<<OVER TEMPERATURE!! >>
5
<<ELECTRIC CHARGE!! >>*
6
<<NO RESPONSE FROM
TRANSCEIVER UNIT!! >>
*: These messages are not erased even if an alarm/warning of higher priority occurs.
Level
Alarm
Meaning: Ship's speed exceeded the
threshold speed (see section 9.2.9) when
the transducer is extended.
Remedy: Silence the buzzer. Lower the
ship's speed.
Behavior: The window disappears.
Alarm
Meaning: Ship's speed exceeded the
threshold speed (see section 9.2.9) when
the transducer is being raised/lowered.
Remedy: Silence the buzzer. Lower the
ship's speed.
Behavior: The window disappears.
Message
10. MAINTENANCE
Meaning, Remedy
Remarks
Remains on-screen until the
cause is removed or rectified.
Remains on-screen until the
cause is removed or rectified.
Remains on-screen until the
cause is removed or rectified.
10-7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fsv-75-3d

Table of Contents