Furuno FSV-24 Installation Manual
Furuno FSV-24 Installation Manual

Furuno FSV-24 Installation Manual

Color scanning sonar
Hide thumbs Also See for FSV-24:

Advertisement

COLOR SCANNING SONAR FSV-24/24S
SAFETY INSTRUCTIONS ...........................................................................i
SYSTEM CONFIGURATION .....................................................................iii
EQUIPMENT LISTS ...................................................................................v
1. MOUNTING THE EQUIPMENT........................................................ 1-1
1.1 Mounting the Hull Unit......................................................................................................1-1
1.2 Mounting the Display Unit ................................................................................................1-8
1.3 Mounting the Transceiver Unit........................................................................................1-14
1.4 Mounting the Power Supply Unit ....................................................................................1-14
1.5 Grounding the Equipment ..............................................................................................1-15
1.6 Installing Attachment Flange (option) .............................................................................1-15
1.7 Mounting the Cable for Extension Kit (option) ................................................................1-18
1.8 Attachment Kit (option) ...................................................................................................1-19
2. WIRING............................................................................................ 2-1
2.1 How to Use the Crimping Tool, Pin Extractor....................................................................2-1
2.2 Location of Connectors ....................................................................................................2-2
2.3 Monitor Unit .....................................................................................................................2-4
2.4 Processor Unit .................................................................................................................2-8
2.5 Transceiver Unit .............................................................................................................2-14
2.6 Power Supply Unit .........................................................................................................2-17
2.7 Cable for Extension Kit...................................................................................................2-17
3. ADJUSTMENT AND CHECK........................................................... 3-1
3.1 Hull Unit Check ................................................................................................................3-1
3.2 Heading Adjustment .........................................................................................................3-4
3.3 Configuring Own Ship Mark .............................................................................................3-6
3.4 Other SYSTEM Menu Items.............................................................................................3-8
3.5 CONE Board Setting in the Processor Unit ....................................................................3-12
3.6 DIP Switch Setting .........................................................................................................3-13
3.7 Testing TX/RX Independently at hull unit ........................................................................3-15
Check List............................................................................................AP-1
PACKING LISTS .................................................................................... A-1
OUTLINE DRAWINGS ........................................................................... D-1
INTERCONNECTION DIAGRAMS......................................................... S-1
Installation Manual
www.furuno.co.jp
Back

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FSV-24 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Furuno FSV-24

  • Page 1: Table Of Contents

    COLOR SCANNING SONAR FSV-24/24S SAFETY INSTRUCTIONS ...i SYSTEM CONFIGURATION ...iii EQUIPMENT LISTS ...v 1. MOUNTING THE EQUIPMENT... 1-1 1.1 Mounting the Hull Unit...1-1 1.2 Mounting the Display Unit ...1-8 1.3 Mounting the Transceiver Unit...1-14 1.4 Mounting the Power Supply Unit ...1-14 1.5 Grounding the Equipment ...1-15...
  • Page 2 Nishinomiya, 662-8580, JAPAN Telephone : +81-(0)798-65-2111 : +81-(0)798-65-4200 Printed in Japan All rights reserved. Pub. No. IME-13180-L (YOSH ) FSV-24/24S The paper used in this manual is elemental chlorine free. ・FURUNO Authorized Distributor/Dealer A : APR L : JUN . 15, 2007...
  • Page 3: Safety Instructions

    The installer of the equipment is solely responsible for the proper installation of the equipment. FURUNO will assume no responsibility for any damage associated with improper installation. WARNING Install the specified transducer tank in accordance with the installation instructions.
  • Page 4 CAUTION Maximum speed while the transducer is projected and being raised or lowered is as below, to prevent damage to the transducer. Projected 1200 mm stroke Max. 18 kt Max. 15 kt 1600 mm stroke Max. 15 kt Max. 12 kt Observe the following compass safe distances to prevent interference to a magnetic compass:...
  • Page 5: System Configuration

    SYSTEM CONFIGURATION Standard type MONITOR UNIT FSV-2400 Loudspeaker Sub Monitor Echo Sounder, Current Indicator, other Navigator 1 Navigator 2 External Interface CS-120A (already installed) Note 1 100/110/115/ 220/230 VAC, 1 50/60 Hz POWER TRANSCEIVER SUPPLY UNIT FSV-241E FSV-242 100/110/115/ 220/230 VAC, 1 50/60 Hz Note 1: Power Kit FSV-2403 (option, installed in processor unit) required to connect CS-120A.
  • Page 6 Black box type Loudspeaker Sub Monitor Echo Sounder, Current Indicator, other Navigator 1 Navigator 2 External Interface CS-120A (already installed) Note 1 100/110/115/ 220/230 VAC, 1 50/60 Hz POWER TRANSCEIVER SUPPLY UNIT UNIT FSV-241E FSV-242 100/110/115/ 220/230 VAC, 1 50/60 Hz Note 1: Power Kit FSV-2403 (option, installed in processor unit) required to connect CS-120A.
  • Page 7: Equipment Lists

    Type Code No. 1 set* 000-066-999 000-067-006 000-067-007 Q’ty Remarks 21” color monitor w/cable For FSV-24 For FSV-24S 1200 mm stroke 1600 mm stroke For system with monitor CP10-04501, 10S2074, CP10-04502, CP10-04503, CP10-04505, CP10-04506, 10S2078 For system with monitor CP10-04501, 10S2075,...
  • Page 8 Options Name Monitor Unit FSV-2400-10 FSV-2400-30 Control Unit FSV-2401-E-5 FSV-2401-E-10 37 cores Cable 10S1258 E/S Interface VI-1100A Net Zonde Junction CS-170 Power Supply Kit FSV-2403 NMEA Cable MJ-A6SPF0012-100C 000-154-037-10 MJ-A6SPF0012-050C 000-154-053-10 E/S cable VVS 0.3X8C *6M* OP10-22 Attachment Flange OP10-23 Attachment Kit OP10-24 Loudspeaker...
  • Page 9: Mounting The Equipment

    The space shown in the figure on the next page is required around the hull unit for wiring and maintenance. If the ambient temperature of the unit is below 0 C, provide the sonar compartment with a heater to keep the temperature above 0 C.
  • Page 10 1300 Heater Insulator Maintenance space, example sonar compartment Note: After mounting the equipment, install stays for anti-vibration. See page 1-7.
  • Page 11 1.1.2 Shortening the retraction tank The retraction tank is 1300 mm in length when supplied. Shorten the tank as necessary so that the transducer is placed well below the keel when it is fully lowered. The following table provides guidelines for shortening the tank. Refer also to the retraction tank installation drawing at the back of this manual.
  • Page 12 1.1.3 Remarks for installation of retraction tank 1. Make, if possible, the installation location a double bottom structure. 2. Install, if possible, the tank on the keel where the tank can be most firmly fixed. 3. Install the reinforcement ribs as near as possible to the top of the retraction tank, allowing space for tightening of bolts and nuts.
  • Page 13 1.1.4 Installing hull unit on retraction tank After welding the retraction tank and allowing sufficient time for cooling, install the hull unit as follows. 1. Clean the hull unit flange, the O-ring and O-ring groove. Coat them with a slight amount of grease. Place the O-ring in position on the tank flange. 2.
  • Page 14 Hex. Nut Spring Washer Flat Washer Bow Mark Hull Unit Flange O-ring Tank Flange Flat Washer Hex. Bolt Hex. Nut Spring Washer O-ring Flat Washer O-ring Retraction Tank Flat Washer Hex. Bolt Hex. Nut Spring Washer Stern side (seven locations) Bow side (17 locations) Installation of hull unit...
  • Page 15 1.1.5 Installing stays (anti-vibration measure) Install stays from the top of the hull unit to the ship’s hull. The stays should be angle iron with a size of 75X75X9 mm or more and at least two pieces should be used; one each to ship’s bow and stern directions. Install if possible, two more stays in ship’s transverse direction.
  • Page 16: Mounting The Display Unit

    Mounting the Display Unit The display unit is composed of the processor, monitor and control units. 1.2.1 Processor unit Mounting considerations When selecting a mounting location, keep in mind the following points: The processor unit must be mounted upright. Locate the unit out of direct sunlight and away from heat sources because of heat that can build up inside the cabinet.
  • Page 17: Monitor Unit

    Mounting procedure 1. Unfasten two bolts from the bottom of the front side of the processor unit, and pull the unit toward you to separate the unit from the mounting base. 2. Fasten six bolts (M6x20, supplied as installation material) to install the mounting base.
  • Page 18 Mounting procedure 1. Drill four holes of 12 mm in diameter in the mounting location, referring to the outline drawing for mounting dimensions. 2. Unfasten two M4X10 screws to dismount the front cover. 3. Unfasten two sets of M10 bolts, plain washers and spring washers to separate the monitor from the mounting base.
  • Page 19: Control Unit

    Attaching the CRT filter 1. Attach two spacer (5x2.5, supplied) with screws (M5x10, supplied) to the location shown below. 2. Screw two hood retainer (supplied) into the filter (supplied). 3. Turn two washers (Ф12, supplied) into two hood retainer attached at step 2. 4.
  • Page 20 (2) Fixing without KB fixing plate 1) Drill four mounting holes of 6 mm diameter to fasten the control unit, referring to the outline drawing at the back of this manual. 2) Make a cutout in the mounting location large enough to accommodate the name plate so the control unit will lie flat.
  • Page 21 Passing the cable through the bottom of the control unit For permanent mounting ((2) and (3) above), the control cable can be passed through the bottom of the control unit. Do the steps in below. 1. Unfasten eight screws (M4) to remove the cover from the bottom of the control unit.
  • Page 22: Mounting The Transceiver Unit

    Mounting the Transceiver Unit The transceiver unit should be mounted on a mounting base (shipyard supply) whose dimensions are as shown in the outline drawing of the transceiver unit at the back of this manual. The transceiver unit should be reinforced against vibration by stays extending from the eyebolts on the top of the unit.
  • Page 23: Grounding The Equipment

    Grounding the Equipment The power supply unit, processor unit and hull unit have protective grounding. Ground the units with a ground wire (IV-8SQ, local supply) or copper strap to prevent electrical shock. Ground the monitor unit and transceiver unit with a ground wire (IV-8SQ, local supply) or copper strap fastened to the ship’s superstructure.
  • Page 24 Procedure 1. Clean the hull unit flange, O-ring and O-ring groove. Coat them with a slight amount grease. 2. (1200 mm stroke) Use 24 hex. bolts, 48 hex nuts, flat washers and spring washers to fasten the attachment flange to retraction tank. (1600 mm stroke) 24 bolts have already been fitted.
  • Page 25 Attachment flange for 1600 mm stroke transducer, sectional view Hex. Bolt Flat Washer Hull Unit Flange O-ring Flat Washer Spring Washer Hex. Nut Attachment Flange O-ring Existing Tank Flat Washer Spring Washer Hex. Nut *: FSV-244E only 1-17...
  • Page 26: Mounting The Cable For Extension Kit (Option)

    Mounting the Cable for Extension Kit (option) For extension of the transducer cable between the hull unit and the transceiver unit, use the extension cable kit (option). The kit is available in 5 and 15 meter lengths. Name: Cable for Extension Kit, Type: FSV-2451, Code No.: 000-067-030 Name Junction box Cable assembly...
  • Page 27: Attachment Kit (Option)

    Attachment Kit (option) When using the retraction tank of FSV-243E/244E for FSV-247/248, the optional attachment kit OP10-24 is necessary. Name: Attachment kit Type: OP10-24 Code no.: 006-943-530 Name Insulation gasket Insulation gasket (2) 1. Clean the hull unit flange, the O-ring and O-ring groove. Coat them with a slight amount of grease.
  • Page 28 Flange of the hull unit O-ring Insulation gasket (1) Insulation gasket (2) Flat washer Spring washer Hex. nut Hex. nut Stern side (Seven locations) 1-20 Spring washer O-ring Insulation gasket Insulation gasket (2) Flat washer Spring washer Using the optional attachment kit Hex.
  • Page 29: Wiring

    WIRING How to Use the Crimping Tool, Pin Extractor A special crimping tool is necessary for connection of wires to the contact pins of the 38P connector. The pin extractor removes the contact pin from the connector body. This paragraph describes how to crimp and extract the contact pin. Crimping Tool 06-1001-016 2.1.1...
  • Page 30: Location Of Connectors

    Location of Connectors MONITOR UNIT 10S2076 (5/10 m) FSV-2400 10S2074 (10 m) or 10S2075 (30 m) Transceiver unit Monitor unit Control unit Monitor unit Control unit External monitor Processor unit clamp TRANSCEIVER UNIT FSV-241E DPYCY-4 *3: Japan Industrial Standard cable *4: The same type of connector is fitted at each end, however the connector where the amount of sheath removed is greater should be connected to the transceiver unit.
  • Page 31 0.46m 0.48m 0.5m 10S2140 13.3m 13.3m Hull unit side *: Cable length between the transceiver and hull unit. Transceiver unit side 0.38m 0.07m 7.2m 10S2141 14.5m 0.07m 0.28m Raise/lower control box of the hull unit side Clamp point 10S2078 Clamp point...
  • Page 32: Monitor Unit

    Monitor Unit 2.3.1 Fabrication of monitor cable 10S2074 (10 m)/10S2075 (30 m) SHIELD 11 12 Fabrication of connector 00-8016-038-313761HV (CN-A303) Vinyl Sheath ANTICORROSIVE SHEATH 1. GRY (No.1) 9. GRY (No.5) 2. BLK/WHT 10. BLK/BLU 3. GRY (No.2) 11. BLK/BRN 4. BLK/RED 12.
  • Page 33 Positioning guide pins Guide pins of the connector identify the mating receptacle. They are; Guide pin A (Large): 4 Guide pin B (Small): 1 Assembling BNC connector (CN-A304 to 308) 1. Remove vinyl sheath of the cable by 7.5 mm. 2.
  • Page 34 2.3.2 Control cable For FURUNO-supplied monitor, attach the cable from the control unit to the CN-A301 connector on the monitor unit as shown in the next section. For blackbox type, this cable should be connected to the CN-A103 connector in the processor unit.
  • Page 35 2.3.3 How to connect cables to the monitor unit Connect the monitor cable and control cable to the monitor (FURUNO-supplied monitor) unit as below. 1. Unfasten four screws (M4x10) at the rear of the monitor to loosen the cable cover.
  • Page 36: Processor Unit

    Processor Unit Cables (10S2074, 10S1258-1 and control cable) from the various units are connected to the CONE Board (10P6905) via the cable clamp (See page 2-2). 2.4.1 10S1258-1 cable This cable runs between the processor unit and transceiver unit. SHIELD CAUTION Divide cables attached to the back of the processor unit between right and left side.
  • Page 37 Fabrication of connector 00-8016-038-313761HV (CN-A101) Shield Vinyl Sheath Core Fabrication of connector 00-8016-038-313761HV Positioning guide pins Guide pins of the connector identify the mating receptacle. They are; Guide pin A (Large): 1 Guide pin B (Small): 1 2.4.2 Power cable Attach the NCS-253-P connector (CN-A110) to the power cable DPYCY-1.5 (Japan Industrial Standard (JIS) cable) or the equivalent for connection the ship’s mains.
  • Page 38 Solder lead wire to armor and connect it to #1 pin of connector. 2.4.3 Monitor cable (10S2074 or 10S2075) Connect the monitor cable 10S2074 or 10S2075 (from the monitor unit) to the connectors in the processor unit shown below. 38P connector: D-sub 25 pin: D-sub 15 pin: 2.4.4...
  • Page 39 2.4.5 Optional equipment With connection of navigator and electronic fishing equipment, the function of the FSV-24 is expanded to include true motion presentation, target lock, echo sounder picture, FNZ marker presentation and digital indication of position, water temperature and depth.
  • Page 40 Cable with armor Armor Vinyl sheath Solder unused cores and earth to braided shield. Wind vinyl tape. Cable without armor Solder unused cores and earh wire to braided shieeld. 2-12 J5 (CIF1) J7 (GYRO) J8 (LOG) J10 (FNZ) J13 (EXT-KP) 8 cm 2 cm 1 cm...
  • Page 41 Synchronizing with echo sounder or other sonar To synchronize the transmission of the FSV-24 with an echo sounder or other type of sonar, make connections as shown below. For current driven KP input Processor unit EXT-KP-IN-H EXT-KP-IN-C For voltage driven KP (12 V) input...
  • Page 42: Transceiver Unit

    Transceiver Unit 2.5.1 Fabrication of connector 00-8016-038-313761HV (CN-B101) Vinyl Sheath Shorten the unused wires appropriately and treat their ends with vinyl tape to prevent short circuit. Positioning guide pins Guide pins of the connector identify the mating receptacle. They are; Guide pin A (Large): 1 Guide pin B (Small): 1 2-14...
  • Page 43 2.5.2 Fabrication of power cable type DPYCY-4 (TB-B101) Fabricate the cable DPYCY-4 as below for connection to the power unit. Anticorrosive sheath 2.5.3 Hull control cable (10S2078) Connect the hull control cable (10S2078) to the CN-B102. Note: The same type of connector is fitted at each end, however the connector where the amount of sheath removed is greater should be connected to the transceiver unit.
  • Page 44 2.5.4 Connection 1. Open the transceiver unit cover. 2. Plug the XH connectors at the end of signal cables (10S2140, 10S2141) into the proper receptacles in the transceiver unit, referring to the labels on the cables and numbers on the TRX board. 3.
  • Page 45: Power Supply Unit

    Power Supply Unit Connect the power cable DPYCY-4 or equivalent as below. Ship's mains Lay the armor of cable in the clamp. Cable for Extension Kit The standard length of the cable between the hull unit and transceiver unit is 5 meters.
  • Page 46 3. Starting from the right side of the junction box, fix the cables by CSK clamp, pass them through cable clamps and connect XH connectors to the MTC board. Cable clamp CKS clamp Transducer cable (10S2140/10S2141) 4. Fasten the shield part of the cable with metal clamp. 5.
  • Page 47 2.7.2 Raise/Lower Control Box Connect power cable (3φ) and the transceiver unit cable (10S2078) as shown below. TB-C101 Connect the power cable TPYCY-4 (Japan Industrial Standard) or the equivalent to this board. LED (Red) For detection of phase reversal on 3 phase power cable Confirm LED after completing the installation.
  • Page 48 2-20 Vinyl Sheath Armor sheath (Clamp here by cable clamp.) Power cable fabrication M4(yellow) x 3 FV5.5-4...
  • Page 49: Adjustment And Check

    ADJUSTMENT AND CHECK Hull Unit Check Note: Before conducting this check (at the dry dock) transmission must be stopped. Default setting of TX transmission is OFF. Confirm as follows. 1. Turn on the power, and then press the [MENU] key to show the main menu. 2.
  • Page 50 3. Select INITIAL SETTING and press the [MENU] key. 4. Select YES and press the [MENU] key. 5. Select TEST and press the [MENU] key. 6. Select TX and press the [MENU] key. 7. Select OFF and press the [MENU] key. 8.
  • Page 51 How to check the hull unit 1. Press the POWER ( ) switch on the control unit (for the display unit) to turn on the equipment. Confirm that the lamps above the ON and 2. Confirm that the 5V and UP lamps on the raise/lower control box are lit. 3.
  • Page 52: Heading Adjustment

    8. Check that LEDs on the panel of the raise/lower control box light as follows: a) UP, MD and DN LEDs light when corresponding limit switch is kicked. b) UP and DOWN LEDs light while UP and DOWN switches are pressed and extinguish when switches are released.
  • Page 53 INTERFACE SETTING.. EXT DATA SETTING.. OWN SHIP MARK.. TEST&INITIALIZATION.. TRX SETTING 1.. TRX SETTING 2.. OTHERS.. 4. Use the trackball to select OTHERS and press the [MENU] key. 5. Select HEADING ADJUST and press the [MENU] key. LANGUAGE HEADING ADJUST : 0 ES2 SELECT ES DRAFT OFFSET : 0.0 m EVENT KEY...
  • Page 54: Configuring Own Ship Mark

    Configuring Own Ship Mark Set own ship’s dimensions and the location of the transducer to accurately display the own ship mark on the display. 1. Press the [MENU] key to display the SYSTEM menu. 2. Use the trackball to select OWN SHIP MARK and press the [MENU] key. 3.
  • Page 55 5. Select ! or " and then press the [MENU] key several times to set the ship’s length (15 to 150 m). 6. Select QUIT to finish the setting. 7. Set the SHIP’S WIDTH (5 to 30 m), TD POSITION 1 (5 to 50 m) or TD POSITION 2 (-10.0 to 10.0 m) similarly.
  • Page 56: Other System Menu Items

    Other SYSTEM Menu Items This section shows you how to set up external equipment. Default settings are underlined. 3.4.1 INTERFACE SETTING menu NMEA 1 BAUD RATE Set the transmission rate for the NMEA 1 port. (2400 bps, 4800 bps, 9600 bps, 19200 bps) NMEA 2 BAUD RATE Set the transmission rate for the NMEA 2 port.
  • Page 57 3.4.2 EXT DATA SETTING menu DATE & TIME Select input port of data and time data. (NONE, CIF, NMEA) HEADING Select input port of the heading data. (NONE, AD10S, CIF, NMEA) LOG PULSE Set the pulse rate per 1 nm for the distance pulse signal. (200 p/NM, 400 p/NM) SPEED &...
  • Page 58: Others Menu

    WATER DEPTH Select the input port for the depth data. (NONE, CIF, NMEA) WATER TEMP. Select the input port for the water temperature data. (NONE, CIF, NMEA) WATER CURRENT Select the input port for the water current data. (NONE, CIF, NMEA) WIND Select the format for the wind data.
  • Page 59 LANGUAGE Select the language. (JAPANESE, ENGLISH) HEADING ADJUST See “3.2 Heading Adjustment”. ES2 SELECT Select the equipment connected to the ES2 port among echosounder and net recorder. (ES, NET REC) ES DRAFT OFFSET When connecting echosounder, set the ship’s draft line to use depth from draft rather than depth from transducer.
  • Page 60: Cone Board Setting In The Processor Unit

    FSV-24. 3. For E/S 2, adjust R119 to suppress noise, and then adjust R167 so that the picture condition is similar to that of echo sounder connected to the FSV-24. 3.5.2 Adjusting the volume of audio alarm The audio alarm volume cannot be adjusted from the control unit.
  • Page 61: Dip Switch Setting

    DIP Switch Setting 3.6.1 CIF2/NMEA2 connector interface selection The signal format of the CIF2/NMEA2 port at the back of the processor unit can be set for CIF or NMEA by DIP switch S2-8 on the IFES Board (10P6903). The default format is OFF (CIF). DIP switch setting S2-#8: ON S2-#8: OFF...
  • Page 62 Input port ES2/NET Note: SIGOUT (AC signal) terminal and REC terminal (DC signal) in the output port are provided for FURUNO echosounder. Therefore, when using SIGOUT terminal, it is not necessary to change jumper setting. 3-14 DIP switch S3 - #1...
  • Page 63: Testing Tx/Rx Independently At Hull Unit

    Testing TX/RX independently at hull unit To check the Tx/Rx function of the hull unit independently, follow the steps below. Note: This test should not be done at the dry dock. The transducer will be damaged. 1. Turn ON DIP switch S3#1 on the TRCPU Board (10P6926) in the transceiver unit.
  • Page 64 This page is intentionally left blank.
  • Page 65: Connecting The External Interface Cs-120A

    CONNECTING THE EXTERNAL INTERFACE CS-120A When upgrading from the CSH-20 series sonar, the External Interface CS-120A can be used. Connect between the processor unit and the CS-120A as shown below. However, we recommend to connect external device to processor unit, instead of using the CS-120A, to avoid signal delay.
  • Page 66 2. Remove two upset screws, detach the plugs J503, J502, J501, J504, J506 and J507, thus pull out the power block. VH4P Power supply Upset screws M5x25 SUS 2 pcs. 3. Fix the power supply pcb (supplied) to the power block with spacers (supplied).
  • Page 67 7. Connect between the processor unit and CS-120A as follows. Processor Unit +24V_H +24V_C CIF_TXD_H CIF_TXD_C CIF_RXD_H CIF_RXD_C SHIELD Note: Echosounder should be connected to the processor unit directly. 8. Set the DIP switch as follows. Input port DIP switch setting CIF1 S3-#2: ON NMEA 2/CIF 2...
  • Page 68: Check List

    Check List Ship Name SCANNING TYPE FSV-24 SONAR Monitor unit (FSV-2400) Control unit (FSV-2401) Processor unit (FSV-2402) Transceiver unit (FSV-241E) Power supply unit (FSV-242) Hull unit (FSV-243E/244E ) Reference Frequency 24KHz Transducer location Note: CHECK ITEMS Unit installation All units are installed according to installation manual.
  • Page 69 DATA SHEET 1 General check CK; DT: digital tester AT: analog tester OS:oscilloscope WC:watch Check item Content Connection All connection should be checked refering to the interconnection diagram. Grounding All grounding should be checked by installation manual. Power Supply(ship’s main voltage) Unit Check point Processor unit...
  • Page 70 DATA SHEET 2 DISPALY UNIT (FSV-2400 ) Check item Contents Software Check software version on version the each board DCON 1050714*** DUAL 1050703*** IFES 1050711*** 1050685*** TRCPU 1050717*** 1050665*** to 1050684*** TRANSCEIVER UNIT(FSV-241) Check item Contents TX output Check transmission output power voltage at following conditions: Range: 1000m...
  • Page 71 DATA SHEET 3 User menu H-scan setting Range Gain Tilt Tx interval Pulse length Tx output TVG near TVG middle TVG far 2AGC Echo average Color Color curve Write by color response curve sheet. Display gain Delete color Far TVG curve Beamwidth-H V-scan setting Range...
  • Page 72 TRX setting1 TRX setting1 TX weight RX weight-H RX weight-V Auto filter Bandwidth COR start distance COR window length Gain at COR TRX setting2 TRX setting2 Near TVG curve-H Near TVG curve-V Near gain-H Near gain-V Pre TVG-H Pre TVG-V Post TVG-H Post TVG-V Absorption coeff.
  • Page 73 工事材料表 INSTALLATION MATERIALS 番 号 名  称 NAME コネクタ(8016) CONNECTOR(8016) コンタクト ピン(8017) CONTACT PIN (8017) コネクタ(BNC) CONNECTOR(BNC) コネクタ(XM2) CONNECTOR(XM2) コネクタフード(XM2) CONNECTOR HOOD 型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりませ ん。 TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER PRODUCT.
  • Page 74 工事材料表 INSTALLATION MATERIALS 番 号 名  称 NAME コネクタ(8016) CONNECTOR(8016) コンタクト ピン(8017) CONTACT PIN (8017) 六角スリワリ セムスB HEX.BOLT (SLOTTED,WASHER HEAD) コネクタ(NCS) CONNECTOR(NCS) 型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりません。 TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER PRODUCT. QUALITY IS THE SAME.
  • Page 75 工事材料表 INSTALLATION MATERIALS 番 号 名  称 NAME コネクタ(8016) CONNECTOR(8016) コンタクト ピン(8017) CONTACT PIN (8017) 圧着端子 CRIMP-ON LUG アース板 COPPER STRAP 型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりません。 TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER PRODUCT. QUALITY IS THE SAME.
  • Page 76 工事材料表 FSV-247/248 INSTALLATION MATERIALS 番 号 名  称 NAME 圧着端子 CRIMP-ON LUG Oリング O-RING バネ座金 SPRING WASHER 六角ナット 1種 HEX.NUT ミガキ平座金 FLAT WASHER 六角ボルト HEX.BOLT アース板 COPPER STRAP 型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりません。 TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER PRODUCT. QUALITY IS THE SAME.
  • Page 78 工事材料表 INSTALLATION MATERIALS 番 号 名  称 NAME コネクタ(SRCN) CONNECTOR(SRCN) コネクタ(SRCN) CONNECTOR(SRCN) 型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりませ ん。 TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER PRODUCT. QUALITY IS THE SAME. (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) 006-921-290-00 CODE NO.
  • Page 79 工事材料表 INSTALLATION MATERIALS 番 号 名  称 NAME コネクタ(SRCN) CONNECTOR(SRCN) コネクタ(SRCN) CONNECTOR(SRCN) コネクタ(SRCN) CONNECTOR(SRCN) コネクタ(SRCN) CONNECTOR(SRCN) コネクタ(SRCN) CONNECTOR(SRCN) 型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりませ ん。 TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER PRODUCT.
  • Page 80 工事材料表 FSV-24/24S INSTALLATION MATERIALS 番 号 名  称 NAME ケーブル(組品) CABLE ASSY. 型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりません。 TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER PRODUCT. QUALITY IS THE SAME. (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)...
  • Page 81 付属品表 ACCESSORIES 番 号 名  称 NAME KB直付け金具 KB FIXNG PLATE ダストカバーKB DUST COVER KB コネクタシール DUMMY FILM 六角ナット 1種 HEX. NUT バネ座金 SPRING WASHER ミガキ平座金 FLAT WASHER +サラ小ネジ OVAL HEAD SCREW +アプセットUIセムスB +HEX.BOLT (WASHER HEAD) ゴム足 RUBBER FEET 型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりませ ん。 TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM.
  • Page 85 FUSE ヒューズ FUSE GLASS TUBE TYPE MFR'S NAME FURUNO ELECTRIC CO.,LTD. (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) 型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変 わりません。 TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER PRODUCT. QUALITY IS THE SAME.
  • Page 86 OUTLINE PART ヒューズ FUSE MFR'S NAME FURUNO ELECTRIC CO.,LTD. (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) 型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は 変わりません。 TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER PRODUCT. QUALITY IS THE SAME.
  • Page 87 OUTLINE PART ヒューズ FUSE MFR'S NAME FURUNO ELECTRIC CO.,LTD. (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) 型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変 わりません。 TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER PRODUCT. QUALITY IS THE SAME.
  • Page 94 D - 7 Jan. 28, '03...
  • Page 95 D - 8 Jan. 28 '03 Jan. 28, '03...
  • Page 96 Takahashi T Y. Hatai...
  • Page 97 D-10...
  • Page 99 D-12...
  • Page 101: Interconnection Diagrams

    名称 Y.KIMURA Jan. 28 '03 相互結線図 Jan. 28, '03 MASS NAME COLOR SCANNING SONAR INTERCONNECTION DIAGRAM 10-071-0103-0 C1318-C07- A FURUNO ELECTRIC CO., LTD. S - 1 操作部 FSV-2401 CONTROL UNIT XHP-15 CN-A201 4 YEL CN1RXD-H 4 BLK CN1RXD-C 3 GRN...
  • Page 102 *7: CABLE LENGTH BETWEEN THE UNITS: 5m OR LESS. OPTIONAL KIT REQUIRED FOR EXTENSION. TITLE FSV-24/24S T.YAMASAKI カラースキャニングソナー 名称 Y.KIMURA 相互結線図 Jan. 28, '03 MASS NAME COLOR SCANNING SONAR INTERCONNECTION DIAGRAM C1318-C08- A 10-071-0103-0 FURUNO ELECTRIC CO., LTD. S - 2...
  • Page 103 *4: GROUND THRU CONNECTOR CLAMP. *5: SELECT CIF OR NMEA AT S2 #8 ON IFES BOARD. DEFAULT IS CIF (OFF). DRAWN E.MIYOSI Dec. 26 '06 CHECKED TAKAHASHI. T APPROVED Y. Hatai FSV-24/24S/30/30S/84/84L SCALE MASS DWG.No. C1318-C03- N PCS-E68PM PC IF 制御部 PROCESSOR UNIT FSV-2402/2402S...
  • Page 104 S-3A...

This manual is also suitable for:

Fsv-24s