5.2 Status functions

The status functions are bit fields (values) and single bits
(signals) in the I/O table. They are set by the welder system
and read by the robot.
Table 5.2 Status functions in the A3 MIG Welder system
Value range
Function
Bits
Status values

WeldingCurrent

16
0
1000

WeldingVoltage

16
0
1000
ErrorNumber
8
0
255
Status signals
Ready
1
PowerSourceReady
1
CycleOn
1
ArcOn
1
TouchSensed
1
Error
1
CollisionDetected
1
5.2.1 WeldingCurrent
This 16-bit function represents the average welding
current measured during the process. The value is in
scaled or non-scaled mode, depending on the user setup.
In non-scaled mode:
• The minimum value is 0 A.
• The maximum value is 1000 A.
• The minimum step is 1 A.
In scaled mode:
1
1 A
• The minimum value is 0 (0 A).
1
0.1 V
• The maximum value is the
1
which is interpreted as 1000 A.
• The minimum step is 1. The welding current is
calculated from the function value by means of
the value scaling formula.
© Kemppi Oy 2020
5.2.2 WeldingVoltage
This 16-bit function represents the average welding
voltage measured during the process. The value is in
scaled or non-scaled mode, depending on the user setup.
In non-scaled mode:
In scaled mode:
robot scaling
value,
15
A3 MIG Welder
• The minimum value is 0 (0.0 V).
• The maximum value is 1000 (100.0 V).
• The minimum step is 1 (0.1 V).
• The minimum value depends on the scaled value
range and is interpreted as 0.0 V.
• The maximum value is the
robot scaling
which is interpreted as 100.0 V.
• The minimum step is 1. The welding voltage is
calculated from the function value by means of
the value scaling formula.
value,