Still Water Option - Cornelius Nueva Tower Installation And Service Manual

Table of Contents

Advertisement

5.5

Still water option

For units with built-in soda dispensers, there is an option of converting the soda dispensers to still water in order to dispense non-
carbonated beverages at individual dispensing valves.
The procedure is described here using the connection of a soda dispenser as an example.
NOTICE!
For units with 5 or 6 dispensing valves, the still water option is only available on the last three dispensing
valves on the right.
For units with 8 dispensing valves, the still water option is only available on the last four dispensing valves
on the right.
Prerequisites
The hood has been removed.
The dispensing valve to be assigned the still water option has
been removed.
Spare parts
Locking screw
Nozzle
Nozzle
Tubing clamp
Seal for locking screw
1. a. n. = as needed
1. Remove the connection (Fig. 16/1) from the soda dispenser (Fig. 16/2).
2. Place the seal (Fig. 17/3) over the locking screw (Fig. 17/4) and close the connection (Fig. 17/
2) of the soda dispenser (Fig. 17/1) using the locking screw (Fig. 17/4).
3. If available, attach to an unused tube (Fig. 18/3) of the python a nozzle (Fig. 18/1) and attach
the tube (Fig. 18/3) using a clamp (Fig. 18/2) to the nozzle (Fig. 18/1).
Otherwise, install a new tube (Fig. 18/3) in the python.
4. Position the still water tube within the dispensing valve support.
5. Insulate the soda dispenser and the still water tube.
6. If applicable, connect the still water tube to the undercounter cooler; see the document "Un-
dercounter cooler installation and service manual".
Finishing tasks
1. Install the hood; see chapter 7.6.
2. Mount the dispensing valve; see the dispensing valve documentation.
Cornelius Deutschland GmbH
Document no. TD0003100
Version 18/03/2019, Index 0
References
see chapter 7.6
See dispensing valve documentation
ID/reference
Qty/
amount
1
220094713
a. n.
149837500
a. n.
318971000
a. n.
440000306
a. n.
317015000
a. n.
Comment
Metric connections
Inch-based connections
6.07 x 1.78
Fig. 16
Fig. 17
1
Fig. 18
Installation and service manual Tower
Installation/removal
1
2
4
3
2
1
3
2
Nueva
13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

220096999

Table of Contents