Commissioning/Shutdown; Commissioning - Cornelius Nueva Tower Installation And Service Manual

Table of Contents

Advertisement

8

Commissioning/shutdown

DANGER!
Risk of personal injury and equipment damage due to non-compliance with safety information!
Failure to observe the safety information will result in a risk of bringing about operating conditions at the unit,
which may cause personal injury or equipment damage.
Please always strictly observe all safety measures and information/instructions; see chapter 1.
NOTICE!
All installation, maintenance and repair work at the unit is to be carried out by an expert only.
WARNING!
Risk of personal injury and equipment damage due to operation by non-qualified staff!
It is dangerous for non-qualified staff to operate the unit!
Service operations on this unit may only be carried out by trained and certified experts who have been
trained in carrying out service operations on this unit.
All wiring and plumbing must be carried out in compliance with national and local laws, regulations and
guidelines. Non-compliance with these laws, regulations and guidelines may result in death, serious injury
or equipment damage.
8.1

Commissioning

NOTICE!
The following describes how the unit is put back into service by an expert following a longer shutdown period
(> 24 hours).
If the unit is to be put back into operation after a temporary shutdown (< 24 hours), this may be carried out by
the operator or user; see the document "Tower operator manual", document no. TD0003000.
Prerequisites
The undercounter cooler has been put into service.
The unit has been installed correctly.
The unit has been connected to the mains supply.
Required tools/materials
Undercounter cooler installation and
service manual
Operator manual
Undercounter cooler
Operator manual
Tower
NOTICE!
Maximum operating pressure of the valves is 100 PSI (689.48 kPa).
1. Turn the key switch (Fig. 43/1) to position "I".
The unit will power up.
If the unit does not power up, see chapter 9.
2. Clean the tubes and valves; see chapter 6.2.
3. Clean the outside of the unit; see the document "Tower operator manual", document no.
TD0003000.
4. If applicable, carry out the configuration settings for the dispensing valves; see dispensing
valve documentation.
Installation and service manual Tower
Nueva
24
References
See the document "Undercounter cooler installation and ser-
vice manual".
see chapter 5.3
see chapter 5.3
ID/reference
Qty/
amount
Document no.
1
Various
Document no.
1
Various
Document no.
1
TD0003000
Commissioning/shutdown
Comment
Fig. 43
1
Cornelius Deutschland GmbH
Document no. TD0003100
Version 18/03/2019, Index 0