8.2

Shutdown

NOTICE!
The following describes how the unit is shut down by an expert for a longer period (> 24 hours).
If the unit is to be shut down temporarily (< 24 hours), this may be carried out by the operator or user; see the
document "Tower operator manual", document no. TD0003000.
Required tools/materials
Operator manual
Tower
Operator manual
Undercounter cooler
1. Clean the tubes and valves as described in chapter 6.2 up to and including Step 11.
2. Drain the unit as follows:
a) Empty the cleaning container.
b) Connect the valve of the water supply; see documentation on the water system.
c) Keep dispensing beverages for each brand until only CO
nozzle.
d) Disconnect all basic ingredient/beverage tubes of the undercounter cooler from the clean-
ing container.
e) Connect all basic ingredient/beverage tubes to the undercounter cooler; see the document
"Undercounter cooler installation and service manual".
f)
Shut down the undercounter cooler; see the document "Undercounter cooler operator
manual".
3. Clean the outside of the unit; see the document "Tower operator manual", document no. TD0003000.
4. Disconnect the unit from power; see chapter 4.1.
Cornelius Deutschland GmbH
Document no. TD0003100
Version 18/03/2019, Index 0
ID/reference
Qty/
amount
Document no.
1
TD0003000
Document no.
1
Various
comes out of the dispensing
2
Commissioning/shutdown
Comment
Fig. 44
Installation and service manual Tower
Nueva
25