Wire The Frequency Input - Emerson Micro Motion 5700 Installation Manual

With configurable outputs, all installation types integral, 4-wire, and 9-wire
Hide thumbs Also See for Micro Motion 5700:
Table of Contents

Advertisement

Installation Manual
MMI-20027478
4.9.2
Wire the Discrete Input (externally powered)
Procedure
Wire to the appropriate input terminal and pins.
Figure 4-26: Discrete Input wiring (externally powered)
A
A. Discrete Input
B. Channel C or D
C. 30 VDC (maximum)
Note
Maximum positive threshold is 3 VDC.
Minimum negative threshold is 0.6 VDC.
4.10

Wire the Frequency Input

Use this section to wire the Frequency Input in explosion-proof, nonincendive, or
nonhazardous installations.
Important
Meter installation and wiring should be performed only by suitably-trained personnel.
4.10.1
Wire the Frequency Input (internally powered)
Procedure
Wire to the appropriate input terminal and pins.
Figure 4-27: Frequency Input wiring (internally powered)
A
A. Frequency Input
B. Frequency Input device
C. (Optional) 1–10 KΩ resistor/open collector
D. (Optional) 3–30 VDC
Installation Manual
B
7
8
Wiring the channels
February 2020
C
B
C
D
37

Advertisement

Table of Contents
loading

Table of Contents