4.6.2
Wire the Discrete Output (externally powered)
Use this procedure to wire the externally-powered Discrete Output for Channel B or C.
Procedure
Wire to the appropriate output terminal and pins.
Figure 4-18: Discrete Output wiring (externally powered)
A
A. Discrete Output
B. Channel B or C
C. 3–30 VDC (maximum)
D. 500 mA current (maximum)
E. Counter
4.6.3
Wire the Discrete Output (internally powered Channel
D)
Procedure
Wire to the appropriate output terminal and pins.
Figure 4-19: Discrete Output wiring (internally powered)
A
A. Discrete Output
B. See
C. Counter
Installation Manual
B
7
8
Figure 4-20
for output amplitude versus load resistance
Wiring the channels