Wiring the channels
February 2020
Figure 4-5: Externally-powered mA Output: maximum loop resistance
A. Maximum resistance (Ω)
B. External supply voltage (V)
4.4

Wire the mA/HART Output

Use this section to wire the mA/HART Output in explosion-proof, nonincendive, or
nonhazardous installations.
Important
Meter installation and wiring should be performed only by suitably-trained personnel.
4.4.1
Wire the mA/HART Output (internally powered)
Procedure
Wire to the appropriate output terminal and pins.
Figure 4-6: mA/HART Output wiring (internally powered)
A
A. mA/HART Output
B. 250–600 Ω resistance
C. HART device
26
1100
1000
900
800
700
A
600
500
400
300
200
100
0
0
1
2
7.5
15.0
22.5
B
Micro Motion 5700 Transmitters with Configurable Outputs
Installation Manual
MMI-20027478
30.0
C
B