Chapter 4 - Operation and Administration
4.11
NPU Parameters Summary
Parameter
Base Station Configuration Parameters
Device Name
Device Location
ATPC Enable/Disable
Optimal Uplink RSSI (dBm)
Operator ID
Cell ID
Base Station Alarms and Traps
Traps Display Filter-Minimum
Severity
Traps Display Filter-Days
Traps Configuration-Admin
Status
Trap Configuration-Severity
178
Table 4-22: NPU Monitor Parameters Summary
Range
Up to 255 printable characters
Up to 255 printable characters
1 - Disable
2 - Enable
Disable is temporary until next reset of the
AUs
-103 to -50
X.X.X
X: 0-255
X.X
X: 0-255
1 - Critical
2 - Major
3 - Minor
4 - Warning
5 - Info
1 - 31 days
1 - Disable
2 - Enable
1 - Critical
2 - Major
3 - Minor
4 - Warning
5 - Info
Default
Run-Time
Updated
Null
Yes
Null
Yes
Enable
Yes
-69
Yes
186.190.0
No
0.250
No
Info
Yes
31 days
Yes
Enable
Yes
Depends on trap
Yes
Operation