Chapter 3 - Commissioning
3.2.3
ODU Power Feeder LEDs
To verify the correct operation of the ODU Power Feeder, examine the LED
indicators located on the front panel of the unit. The following table lists the LEDs
of the ODU Power Feeder and their associated indications.
Name
PWR
ODU PWR 1 - 4
3.2.4
Verifying the Ethernet Connection
Once you have connected the unit to an Ethernet outlet, verify that the Ethernet
Integrity Indicator, which is the yellow LED embedded in the DATA port
connector, is on. This indicates that the unit is connected to an Ethernet segment.
The Ethernet Activity Indicator, which is the green embedded LED, should blink
whenever the unit receives or transmits traffic on the DATA port.
62
Table 3-8: ODU Power Feeder LEDs
Description
Input power indication
Output power indications
Functionality
¢
Off - ODU Power Feeder is not powered
¢
Green - ODU Power Feeder power is OK
¢
Off - AU-ODU-HP is not connected
¢
Red - Power output problem (short or overload)
¢
Green - AU-ODU-HP is connected and powered