Item
Max number of Services per
BST
Min number of data
connections per Service
Max number of data
connections per Service
Max number of data
connections per SU
Max number of data
connections per AU
Max number of SUs per AU
Max number of AUs per BST
Max number of MAC addresses
in Bridging Table
Max number of VLANs per
Service
Max number of VLANs per SU
Max number of VLANs
(VPL IDs) per BST
Max number of concurrent
voice calls per Voice/L2
Service
Max number of concurrent
voice calls per AU
18

Table 1-13: Services

Description
4,095 (0ne or several services may be defined per subscriber, one or more
subscribers can be supported per SU)
2 (1 uplink, 1 downlink)
8 (4 uplink, 4 downlink)
126
3999 - 3 x number of SUs (3 connections are reserved for each SU)
510
7
BST: 6,000
SU: 512
(Aging time is configurable. The default is 3 minutes for SU, 10 minutes for NPU)
16
16
1,024
50
300