To access the Monitor program using Telnet:
The PC used for accessing the Monitor program should be configured
1
according to the parameters configured for the applicable port (MGMT or DATA
port).
If you connect directly to the MGMT or DATA port, use a crossed Ethernet
2
cable.
Run the Telnet program connecting to the IP address of the connected port.
3
The Enter the password message is displayed. Enter the password and press
4
the Enter key to get to the Main menu.
NOTE
Following three unsuccessful login attempts (using incorrect passwords), the monitor program is
blocked for 10 minutes.
If you forgot the Installer or Monitor password, the Administrator can login (with the Administrator
password) and define a new password for Installer and/or Monitor access level.
If you forgot the Administrator password, type "help" to receive a challenge string consisting of 24
characters. Contact Customer Service and provide the challenge string (after user identification) to
receive a temporary password. You can use this password only once to enter the program. The
password must be changed during the session to a different "permanent" password. The
administrator should be notified of this new password. Five consecutive errors in entering the
temporary password will invalidate it. In this case, repeat this procedure to receive a new challenge
string for a new temporary password.
4.2.2

Using the Monitor Program

This section describes the Monitor program structure and navigation rules.
There are three access levels to the Monitor program. The available actions
¢
depend on the access level (password) used for accessing the program:
¯
¯
¯
WiLink-I Modular Base Station System Manual
Administrator: Read/Write permissions for all parameters. The default
password is admin.
Installer: Read-only permission for the Services menu, Read/Write
permissions for all other options excluding the Change Password option.
The default password is installer.
Monitor: Read-only permissions for all parameters. The default password
is monitor.
The Monitor Program
67